Key Features
- Product manufactured under ISO 9001:2015 standards.
- High elevation / Low cost.
- 100% section-by-section assembly inspection.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for high-humidity coastal zones or industrial areas.
Physical Characteristics
-
Maximum Axial Load: 200 kg.
-
Height: 24 meters (8 sections).
-
Wind Resistance: 200 km/h.
-
Corrosion Protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
-
Application: Outdoor (Humid zones).
Includes the following components
| Quantity | Model | Description |
| 8 | STZ30G | 30 cm face tower section. |
| 1 | SCZ30PG | 30 cm tower top with set screw for lightning rod. |
| 1 | SBA30G | Base for 30 cm tower. |
| 1 | SAB30G | Anchor for tower base. |
| 4 | SJB30G | Guy wire support bracket. |
| 3 | SAP02G | Floor anchor for guy wire. |
| 24 | CUELLO-14-HDG | Thimble for guy wire. |
| 72 | NUDO-316-FJG | 3/16' cable clamp. |
Does not include guy wire. 315 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.
Does not include turnbuckles. 12 1/2' x 6' turnbuckles are recommended. (TEN1/2X6OGJ or TEN1/2X6OQJ).
**Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy Anchors will void the equipment warranty, and any additional modifications are the responsibility of the installer.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted in 7 alternating bands of equal size: 4 aviation orange and 3 white.
Lifeline system (Not included)
*NOM-009 mandates the use of fall arrest systems for work on structures.
New! Lightning rod + Grounding kit with cable. LINKEDPRO brand (Not included)
KLP-TZ24-PRO- All-inclusive! Ideal for 24m towers, includes dipole crown, wiring, and electrodes.
You may also quote the following grounding or lightning rod components individually:
Recommended Grounding System for Tower and mounted equipment (Not included)
| Quantity | Model | Description |
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound. |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 1 | TGBUSG10 | Grounding bus bar with 1000A insulators (no cabinet). |
* It is recommended to use 4 AWG gauge sheathed copper cable (SLY-287-GRN) for grounding from the electrode to the tower. For equipment on the tower, 6 AWG gauge (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included)
| Quantity | Model | Description |
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic inspection well. |
| 1 | ANTIOX | Spray for terminal protection. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 16 | TGAC | Insulator for tower. |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for the integration (SLY-346-BLK). Considering an installation of the electrode at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the connection diagram for Physical Ground + Lightning Rod in the following DIAGRAM.
Recommendations
- Ensure the installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting).
- It is recommended to illuminate the tower at least at the top with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images