24 m Guyed Tower Kit with STZ35 Electro-Galvanized Section (Guy wires not included).
- $ 36,099.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: KTZ-35E-024
Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% section-by-section assembly inspection Electroplated galvanized in accordance with ASTM B-633 standards. Ideal for dry, corrosion-free areas...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35E-024 , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standards
- High elevation / Low cost
- 100% section-by-section assembly inspection
- Electroplated galvanized in accordance with ASTM B-633 standards.
- Ideal for dry, corrosion-free areas
Physical Characteristics
- Maximum Axial Load: 350 kg
- Height: 24 meters (8 sections)
- Wind Resistance: 200 km/h
- Anti-corrosive protection: Electrolytic Galvanized (ASTM B-633)
- Application: Outdoor (Desert or low humidity areas)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 8 | STZ35 | 35 cm face width tower section |
| 1 | SCZ35P | 35 cm tower top with lightning rod clamp |
| 1 | SBZ35 | 35 cm tower base |
| 1 | SAB45 | Tower base anchor 35/45 |
| 3 | SJB35 | Guy wire clamp bracket |
| 3 | SAZ45 | Floor anchor for guy wire |
| 18 | CUELLO-14-HDG | Guy wire thimble |
| 54 | NUDO-316-FJG | 3/16' wire rope clip |
Guy wire not included. We recommend 240 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters.
Turnbuckles not included. We recommend 9 turnbuckles of 5/8' x 9'. (TEN5/8X9OGJ or TEN5/8X9OQJ).
Failure to use installation accessories such as brackets, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the sole responsibility of the installer.
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. L810 type |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted in 7 alternating bands of equal size; 4 orange-red and 3 white.
Lifeline System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 27 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged cable clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Grounding System recommended for Tower and mounted equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic junction box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity busbar with insulators (without enclosure) |
* We recommend using 4 AWG jacketed copper wire (SLY-287-GRN) for grounding from the electrode to the tower. For equipment on the tower, you can use 6 AWG (SLY-291-GRN).
Basic Lightning Rod System recommended for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic junction box |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Physical Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and tightening hardware
- Do not install solar panels at a height of more than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in reddish-orange and white, in 7 stripes of equal height starting and ending with reddish-orange (SYSCOM does not perform tower painting work)
- It is recommended to illuminate the tower at least at the tip with a red light
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images