27 m Guyed Floor Tower Kit with STZ30 Electro-Galvanized Section (Guy wires not included).

  • $ 29,099.00
  • Brand: SYSCOM TOWERS
  • Availability: Out of stock
  • SKU: KTZ-30E-027

Key Features Product manufactured under ISO 9001:2015 Standards High elevation / Low cost 100% assembly inspection section by section Electrolytic galvanization in accordance with ASTM B-633 standards Ideal for dry,...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30E-027 , supplier:Syscom , syscom

Logo SYSCOM TOWERS

Key Features

  • Product manufactured under ISO 9001:2015 Standards
  • High elevation / Low cost
  • 100% assembly inspection section by section
  • Electrolytic galvanization in accordance with ASTM B-633 standards
  • Ideal for dry, corrosion-free zones

Physical Characteristics

  • Maximum Axial Load: 200 kg
  • Height: 27 meters (9 sections)
  • Wind resistance: 200 km/h
  • Anti-corrosion protection: Electrolytic Galvanization (ASTM B-633)
  • Application: Outdoor (Desert or low-humidity zones)

Includes the following components

Quantity Model Description
9 STZ30 30 cm face-width tower section
1 SCZ30P 30 cm tower top cap with set screw for lightning rod
1 SBA30 Base for 30 cm tower
1 SAB30 Anchor for tower base
5 SJB30 Guy wire bracket
3 SAP02 Floor anchor for guy wire
30 CUELLO-14-HDG Guy wire thimble
90 NUDO-316-FJG 3/16" wire rope clip

Guy wire not included. 430 meters of 1/8" guy wire (SRET-318-CAM) or larger diameters are recommended.

Turnbuckles not included. 15 turnbuckles (1/2" x 6") are recommended (TEN1/2X6OGJ or TEN1/2X6OQJ)

FAILURE to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy Anchors is considered a voidance of the equipment warranty, and any additional adaptation is the responsibility of the installer.

Complementary Accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. Type L810
2 HLU3R2 Mounting for EIGSLSE obstruction lamp

* The signaling standard dictates that the tower must be painted with 7 stripes of equal size; 4 orange-red stripes and 3 white stripes

Lifeline System (Not included)

Quantity Model Description
1 SHE-LV Pair of fastening brackets
1 S-GULV Line guide
30 SRET-338CAM 3/8" cable
6 NUDO-38FJG 3/8" forged clip
2 CUELLO-38-HDG 3/8" thimble
1 TRY-ACC-SLIDER (Optional) Safety Slider for Installer
1 SYS-USA7B (Optional) Suspension Harness

*NOM-009 makes the use of systems to arrest accidental falls on a structure mandatory

New! Lightning Rod + Grounding Kit with Cable. LINKEDPRO Brand (Not included)

KLP-TZ27-PRO - All included! Ideal for 27 m towers with corona dipole, wiring, and electrodes.

Or you may also quote the following Grounding or Lightning Rod components individually:

Recommended Grounding System for Tower and Mounted Equipment (Not included)

Quantity Model Description
1 TG45AB 45A grounding electrode with Electrode, Filter, and H2Ohm compound
1 S610 Plastic access box
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 1000A capacity busbar with insulators (without enclosure)

* The use of 4 AWG jacketed copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) may be used.

Recommended Basic Lightning Rod System for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp electrode. With a bag of impedance-improving compound (H2OHM), compass, and level
1 S610 Small plastic inspection box
1 ANTIOX Terminal protection spray
3 TGCR11 Eye connector
2 TGAB18 Ground rod connector
18 TGAC Tower insulator

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence

*2/0 gauge copper cable is recommended for the integration (SLY-346-BLK). Considering an installation of the electrode at a maximum of 3 meters from the tower, approx. 8 meters are used

See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM

Recommendations

  • Ensure that the installation is performed by a trained professional
  • Schedule a maintenance plan for checking guy wire tension and tightening bolts
  • Do not install solar panels higher than 6 meters. Check the compatibility between solar cells and mounts
  • A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting)
  • It is recommended to illuminate the tower at least at the tip with a red lamp

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram Version 2.0

Installation Images

Installation Images