27 m Guyed Floor Tower Kit with STZ30 Electro-Galvanized Section (Guy wires not included).
- $ 29,099.00
- Brand: SYSCOM TOWERS
- Availability: Out of stock
- SKU: KTZ-30E-027
Key Features Product manufactured under ISO 9001:2015 Standards High elevation / Low cost 100% assembly inspection section by section Electrolytic galvanization in accordance with ASTM B-633 standards Ideal for dry,...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30E-027 , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 Standards
- High elevation / Low cost
- 100% assembly inspection section by section
- Electrolytic galvanization in accordance with ASTM B-633 standards
- Ideal for dry, corrosion-free zones
Physical Characteristics
- Maximum Axial Load: 200 kg
- Height: 27 meters (9 sections)
- Wind resistance: 200 km/h
- Anti-corrosion protection: Electrolytic Galvanization (ASTM B-633)
- Application: Outdoor (Desert or low-humidity zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 9 | STZ30 | 30 cm face-width tower section |
| 1 | SCZ30P | 30 cm tower top cap with set screw for lightning rod |
| 1 | SBA30 | Base for 30 cm tower |
| 1 | SAB30 | Anchor for tower base |
| 5 | SJB30 | Guy wire bracket |
| 3 | SAP02 | Floor anchor for guy wire |
| 30 | CUELLO-14-HDG | Guy wire thimble |
| 90 | NUDO-316-FJG | 3/16" wire rope clip |
Guy wire not included. 430 meters of 1/8" guy wire (SRET-318-CAM) or larger diameters are recommended.
Turnbuckles not included. 15 turnbuckles (1/2" x 6") are recommended (TEN1/2X6OGJ or TEN1/2X6OQJ)
FAILURE to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy Anchors is considered a voidance of the equipment warranty, and any additional adaptation is the responsibility of the installer.
Complementary Accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction lamp |
* The signaling standard dictates that the tower must be painted with 7 stripes of equal size; 4 orange-red stripes and 3 white stripes
Lifeline System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of fastening brackets |
| 1 | S-GULV | Line guide |
| 30 | SRET-338CAM | 3/8" cable |
| 6 | NUDO-38FJG | 3/8" forged clip |
| 2 | CUELLO-38-HDG | 3/8" thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety Slider for Installer |
| 1 | SYS-USA7B | (Optional) Suspension Harness |
*NOM-009 makes the use of systems to arrest accidental falls on a structure mandatory
New! Lightning Rod + Grounding Kit with Cable. LINKEDPRO Brand (Not included)
KLP-TZ27-PRO - All included! Ideal for 27 m towers with corona dipole, wiring, and electrodes.
Or you may also quote the following Grounding or Lightning Rod components individually:
Recommended Grounding System for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity busbar with insulators (without enclosure) |
* The use of 4 AWG jacketed copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) may be used.
Recommended Basic Lightning Rod System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With a bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection box |
| 1 | ANTIOX | Terminal protection spray |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Ground rod connector |
| 18 | TGAC | Tower insulator |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence
*2/0 gauge copper cable is recommended for the integration (SLY-346-BLK). Considering an installation of the electrode at a maximum of 3 meters from the tower, approx. 8 meters are used
See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM
Recommendations
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and tightening bolts
- Do not install solar panels higher than 6 meters. Check the compatibility between solar cells and mounts
- A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting)
- It is recommended to illuminate the tower at least at the tip with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images