27 m Guyed Floor Tower Kit with STZ35 Electro-galvanized Section (guy wire not included).

  • $ 39,299.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-35E-027

Key Features: Product manufactured under ISO 9001:2015 standards High elevation / Low cost. 100% assembly inspection section by section. Electrolytic galvanization according to ASTM B-633 standards. Ideal for dry, corrosion-free...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35E-027 , supplier:Syscom , syscom

SYSCOM TOWERS

Key Features:

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost.
  • 100% assembly inspection section by section.
  • Electrolytic galvanization according to ASTM B-633 standards.
  • Ideal for dry, corrosion-free areas

Physical Characteristics:

  • Maximum Axial Load: 350 kg.
  • Height: 27 meters (9 sections).
  • Wind Resistance: 200 km/h.
  • Anticorrosive protection: Electrolytic Galvanization (ASTM B-633).
  • Application: Outdoors (Desert areas or low humidity)

Includes the following components:

Quantity Model Description
9 STZ35 Tower section with 35 cm face width.
1 SCZ35P 35 cm tower top with lightning rod set screw.
1 SBZ35 35 cm tower base.
1 SAB45 Anchor for 35/45 tower base.
3 SJB35 Guy wire support bracket.
3 SAZ45 Floor anchor for guy wire.
18 CUELLO-14-HDG Thimble for guy wire
54 NUDO-316-FJG 3/16' cable clamp.

Guy wire not included.

270 meters of 3/16' guy wire are recommended (SRET-474-CAM or SRET-316-DA ) or larger diameters.

Turnbuckles not included

9 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).

*Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy wire anchors is considered a forfeiture of the equipment warranty, and any additional modification is the responsibility of the installer.

Complementary accessories (Not included):

Signaling/Lighting System (Not included):

Quantity Model Description
2 EIGSLSE Autonomous LED strobe type with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mount for EIGSLSE obstruction lamp

*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.

Lifeline system (Not included):

Quantity Model Description
1 SHE-LV Pair of support brackets
1 S-GULV Guide for line
30 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged clamp
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety carriage for installer.
1 SYS-USA7B (Optional) Suspension Harness.

*NOM-009 mandates the use of systems that arrest accidental falls on a structure.

Grounding System Recommended for Tower and Mounted Equipment (Not included):

Quantity Model Description
1 TG45AB 45 A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic access box.
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 Grounding bus bar with insulators, 1000A capacity (without cabinet)

*The use of 4 AWG insulated copper cable (SLY-287-GRN) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Basic Lightning Protection System Recommended for Tower (Not included):

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp electrode. With one bag of impedance improving compound (H2OHM), compass, and level.
1 S610 Small plastic inspection box.
1 ANTIOX Aerosol for terminal protection.
3 TGCR11 Eye connector.
2 TGAB18 Connector for rod.
18 TGAC114 Tower insulator.

*The dipole-type tip offers a 72° protection cone below the coil. Recommended for low lightning incidence areas.

*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.

View Physical Ground + Lightning Rod connection diagram.

Recommendations:

  • Ensure that the installation is performed by a trained professional.
  • Schedule a maintenance plan to check guy wire tension and tighten hardware.
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
  • A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
  • The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting work).
  • It is recommended to illuminate the tower at least at the top with a red lamp.