27 m Guyed Floor Tower Kit with STZ35 Electro-galvanized Section (guy wire not included).
- $ 39,299.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: KTZ-35E-027
Key Features: Product manufactured under ISO 9001:2015 standards High elevation / Low cost. 100% assembly inspection section by section. Electrolytic galvanization according to ASTM B-633 standards. Ideal for dry, corrosion-free...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35E-027 , supplier:Syscom , syscom
Key Features:
- Product manufactured under ISO 9001:2015 standards
- High elevation / Low cost.
- 100% assembly inspection section by section.
- Electrolytic galvanization according to ASTM B-633 standards.
- Ideal for dry, corrosion-free areas
Physical Characteristics:
- Maximum Axial Load: 350 kg.
- Height: 27 meters (9 sections).
- Wind Resistance: 200 km/h.
- Anticorrosive protection: Electrolytic Galvanization (ASTM B-633).
- Application: Outdoors (Desert areas or low humidity)
Includes the following components:
| Quantity | Model | Description |
|---|---|---|
| 9 | STZ35 | Tower section with 35 cm face width. |
| 1 | SCZ35P | 35 cm tower top with lightning rod set screw. |
| 1 | SBZ35 | 35 cm tower base. |
| 1 | SAB45 | Anchor for 35/45 tower base. |
| 3 | SJB35 | Guy wire support bracket. |
| 3 | SAZ45 | Floor anchor for guy wire. |
| 18 | CUELLO-14-HDG | Thimble for guy wire |
| 54 | NUDO-316-FJG | 3/16' cable clamp. |
Guy wire not included.
270 meters of 3/16' guy wire are recommended (SRET-474-CAM or SRET-316-DA ) or larger diameters.
Turnbuckles not included
9 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
*Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy wire anchors is considered a forfeiture of the equipment warranty, and any additional modification is the responsibility of the installer.
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe type with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction lamp |
*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.
Lifeline system (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of support brackets |
| 1 | S-GULV | Guide for line |
| 30 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety carriage for installer. |
| 1 | SYS-USA7B | (Optional) Suspension Harness. |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Grounding System Recommended for Tower and Mounted Equipment (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Grounding bus bar with insulators, 1000A capacity (without cabinet) |
*The use of 4 AWG insulated copper cable (SLY-287-GRN) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for Tower (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With one bag of impedance improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic inspection box. |
| 1 | ANTIOX | Aerosol for terminal protection. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Connector for rod. |
| 18 | TGAC114 | Tower insulator. |
*The dipole-type tip offers a 72° protection cone below the coil. Recommended for low lightning incidence areas.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
Recommendations:
- Ensure that the installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting work).
- It is recommended to illuminate the tower at least at the top with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images