SYSCOM TOWERS
27 m Guyed Floor Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).
27 m Guyed Floor Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standards.
- Great elevation / Low cost.
- 100% inspection of section-by-section assembly.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for coastal areas with high humidity or industrial zones.
Physical Characteristics
- Maximum Axial Load: 350 kg.
- Height: 27 meters (9 sections).
- Wind resistance: 200 km/hr.
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 9 | STZ35G | Tower section with 35 cm face width. |
| 1 | SCZ35PG | 35 cm tower top with set screw for lightning rod. |
| 1 | SBZ35G | 35 cm tower base. |
| 1 | SAB45G | Anchor for 35/45 tower base. |
| 3 | SJB35G | Guy wire bracket. |
| 3 | SAZ45G | Ground anchor for guy wire. |
| 18 | CUELLO-14-HDG | Thimble for guy wire. |
| 54 | NUDO-316-FJG | 3/16' cable clamp. |
Guy wire not included. 270 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Turnbuckles not included. 9 turnbuckles of 5/8' x 9' (TEN5/8X9OGJ or TEN5/8X9OQJ) are recommended.
**Failure to use installation accessories such as brackets, tower base, tower anchor, or guy wire anchors is considered a voidance of the equipment warranty, and any additional modifications are the sole responsibility of the installer.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Self-contained LED strobe with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light. |
* The signaling standard dictates that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white bands.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of fastening brackets. |
| 1 | S-GULV | Cable guide. |
| 30 | SRET-338CAM | 3/8' cable. |
| 6 | NUDO-38FJG | 3/8' forged cable clamp. |
| 2 | CUELLO-38-HDG | 3/8' thimble. |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
* NOM-009 mandates the use of fall arrest systems for structures.
Grounding System Recommended for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound. |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 1 | TGBUSG10 | Busbar with insulators, 1000A capacity (No enclosure). |
* 4 AWG insulated copper cable (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG cable (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for Tower (Not included)
*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering the electrode is installed at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the physical ground + lightning rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure the installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting).
- It is recommended to light the tower at least at the tip with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images