SYSCOM TOWERS
27 m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).
27 m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standards
- Great Elevation / Low cost
- 100% Inspection of Section-by-Section Assembly
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
- Ideal for high-humidity coastal zones or industrial areas
Physical Characteristics
- Maximum Axial Load: 500 kg
- Height: 27 meters (9 sections)
- Wind resistance: 200 km/hr
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid Zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 9 | STZ45G | 45 cm face width tower section |
| 1 | SCZ45G | 45 cm tower top with set screw for lightning rod |
| 1 | SBZ45G | 45 cm tower base |
| 1 | SAB45G | Anchor for 35/45 tower base |
| 3 | SJB45G | Guy wire clamp flange |
| 3 | SAZ45G | Floor anchor for guy wire |
| 18 | CUELLO-14-HDG | Thimble for guy wire |
| 54 | NUDO-14-FJG | 1/4' wire rope clip |
Guy wire not included. 270 meters of 1/4' guy wire (SRET-635-CAM) or larger diameters are recommended.
Turnbuckles not included. 9 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the sole responsibility of the installer.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included):
Lifeline system (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 30 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged wire rope clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety Slider for Installer |
| 1 | SYS-USA7B | (Optional) Full-body suspension harness |
*NOM-009 mandates the use of fall arrest systems on structures.
Grounding System Recommended for Tower and Mounted Equipment (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with rod, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eyelet connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity ground bus bar with insulators (no enclosure) |
* The use of 4 AWG coated copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) may be used.
Basic Lightning Protection System Recommended for Tower (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With one bag of impedance improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection well |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 18 | TGAC114 | Tower insulator |
*The dipole-type rod offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering the electrode is installed at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white tones, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting work)
- It is recommended to light the tower, at least at the tip, with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images