SYSCOM TOWERS
27 m Ground-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).
27 m Ground-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).
Couldn't load pickup availability
Highlighted Features
- Product manufactured under ISO 9001:2015 Standards
- High elevation / Low cost
- 100% Section-by-section assembly inspection
- Hot-dip galvanized according to NMX-H-004-SCFI-2008
- Ideal for high-humidity coastal zones or industrial areas
Physical Characteristics
- Maximum Axial Load: 200 kg
- Height: 27 meters (9 sections)
- Wind resistance: 200 km/hr
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoors (Humid Zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 9 | STZ30G | 30 cm face-width tower section |
| 1 | SCZ30PG | 30 cm tower top with lightning rod set screw |
| 1 | SBA30G | Base for 30 cm tower |
| 1 | SAB30G | Anchor for tower base |
| 5 | SJB30G | Guy wire clamping flange |
| 3 | SAP02G | Floor anchor for guy wire |
| 30 | CUELLO-14-HDG | Thimble for guy wire |
| 90 | NUDO-316-FJG | 3/16' cable clamp |
Guy wire not included. We recommend 430 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters.
Turnbuckles not included. We recommend 15 turnbuckles of 1/2' x 6'. (TEN1/2X6OGJ or TEN1/2X6OQJ).
**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will void the equipment warranty, and any additional adaptation is the installer's responsibility.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white ones.
Lifeline System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of fastening brackets |
| 1 | S-GULV | Line guide |
| 30 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged cable clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety carriage for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
*NOM-009 mandates the use of systems to arrest accidental falls on a structure.
New! Lightning Rod Kit + Physical Ground with Cable. LINKEDPRO Brand (Not included)
KLP-TZ27-PRO - All included! Ideal for 27m towers with corona dipole, wiring, and electrodes.
Or you can quote the following Physical Ground or Lightning rod components individually:
Physical Grounding System Recommended for the Tower and equipment mounted on it (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic registration box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Union bar with 1000A capacity insulators (No cabinet) |
Basic Lightning Rod System Recommended for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With one bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic handhole |
| 1 | ANTIOX | Spray for terminal protection |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 18 | TGAC | Tower insulator |
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and tightening hardware
- Do not install solar panels at a height of more than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white tones, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform the tower painting work)
- It is recommended to light the tower, at least at the tip, with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images