SYSCOM TOWERS
3 m Floor-Mounted Guyed Tower Kit with Electro-Galvanized STZ30 Section (Guy wire not included).
3 m Floor-Mounted Guyed Tower Kit with Electro-Galvanized STZ30 Section (Guy wire not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 Standards
- High Elevation / Low cost
- 100% Section-by-Section Assembly Inspection
- Electrolytic Galvanization in accordance with ASTM B-633 standards
- Ideal for dry, corrosion-free areas
Physical Characteristics
- Maximum Axial Load: 200 Kg
- Height: 3 meters (1 section)
- Wind resistance: 200 km/h
- Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
- Application: Outdoor (Desert or low-humidity areas)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 1 | STZ30 | 30 cm face tower section |
| 1 | SCZ30P | 30 cm tower top cap with lightning rod set screw |
| 1 | SBA30 | Base for 30 cm tower |
| 1 | SAB30 | Anchor for tower base |
| 1 | SJB30 | Guy wire attachment flange |
| 3 | SAP02 | Floor anchor for guy wire |
| 6 | CUELLO-14-HDG | Thimble for guy wire |
| 18 | NUDO-316-FJG | 3/16" wire rope clip |
Does not include guy wire.
20 meters of 1/8" guy wire (SRET-318-CAM) or larger diameters are recommended.
Does not include turnbuckles.
3 turnbuckles of 1/2' x 6' are recommended. (TEN1/2X6OGJ or TEN1/2X6OQJ).
**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy anchors is considered a voiding of the equipment warranty, and any additional adaptation is the responsibility of the installer.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
*Signaling regulations dictate that the tower must be painted in 7 bands of equal size; 4 bands in reddish-orange tone and 3 in white.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 5 | SRET-338 | 3/8" cable |
| 6 | NUDO-38FJG | 3/8" forged wire rope clip |
| 2 | CUELLO-38-HDG | 3/8" thimble |
| 2 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension Harness |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Recommended Grounding System for Tower and Equipment mounted on it (Not included)
* It is recommended to use 4 AWG cal. coated copper cable (SLY-287-GRN) for grounding from the electrode to the tower. For equipment on the tower, 6 AWG cal. can be used (SLY-291-GRN).
Recommended Basic Lightning Protection System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning Rod Tip with Aluminum Mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp Electrode with one bag of impedance improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection well |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 2 | TGAC | Tower insulator |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and adjust hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting)
- It is recommended to illuminate the tower, at least at the top, with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images