Wishlist

3m Ground-Mounted Guyed Tower Kit with STZ35 Electro-Galvanized Section (Guy wires not included).

  • $ 11,299.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-35E-003

Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% assembly inspection section by section Electrolytic galvanized in accordance with ASTM B-633 standards Ideal for dry,...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35E-003 , supplier:Syscom , syscom

SYSCOM TOWERS

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost
  • 100% assembly inspection section by section
  • Electrolytic galvanized in accordance with ASTM B-633 standards
  • Ideal for dry, corrosion-free areas

Physical Characteristics

  • Maximum Axial Load: 350 kg
  • Height: 3 meters (1 section)
  • Wind Resistance: 200 km/hr
  • Anti-corrosive protection: Electrolytic galvanized (ASTM B-633)
  • Application: Outdoor (Desert or low humidity areas)

Includes the following components

Quantity Model Description
1 STZ35 35 cm face width tower section
1 SCZ35P 35 cm tower top cap with lightning rod clamp
1 SBZ35 35 cm tower base
1 SAB45 Anchor for 35/45 tower base
1 SJB35 Guy wire support flange
3 SAZ45 Ground anchor for guy wire
6 CUELLO-14-HDG Thimble for guy wire
18 NUDO-316-FJG 3/16' cable clamp

Guy wire not included. 20 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.

Turnbuckles not included. 3 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).

Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. Type L810
2 HLU3R2 Mounting for EIGSLSE obstruction light

* Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white bands.

Lifeline system (Not included)

Quantity Model Description
1 SHE-LV Pair of mounting brackets
1 S-GULV Line guide
5 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged clamp
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer
1 SYS-USA7B (Optional) Suspension harness

* NOM-009 mandates the use of fall protection systems for structures.

Recommended Grounding System for Tower and Mounted Equipment (Not included)

Quantity Model Description
1 TG45AB 45 A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic junction box
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 1000A capacity ground bus bar with insulators (no enclosure)

* 4 AWG coated copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. 6 AWG cable (SLY-291-GRN) can be used for equipment on the tower.

Recommended Basic Lightning Rod System for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp. electrode with a bag of impedance-improving compound (H2OHM), compass, and level
1 S610 Small plastic junction box
1 ANTIOX Aerosol for terminal protection
3 TGCR11 Eye connector
2 TGAB18 Rod connector
2 TGAC114 Tower insulator

*The dipole-type tip offers a 72° protection cone below the coil. Recommended for low lightning incidence zones.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.

Recommendations

  • Ensure the installation is performed by a trained professional
  • Schedule a maintenance plan to check guy wire tension and tighten hardware
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
  • A stress study must be performed when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
  • The tower must be painted in red-orange and white, in 7 stripes of equal height, starting and ending with red-orange (SYSCOM does not perform tower painting)
  • It is recommended to illuminate the tower at least at the tip with a red lamp

Note: The use of non-original installation accessories voids the equipment warranty, and any additional adaptation is the responsibility of the installer.

Representative Diagram: Guy Wire Installation Version 2.0

Representative Diagram: Guy Wire Installation Version 2.0

Installation Images

Installation Images

Recently viewed