SYSCOM TOWERS
3m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).
3m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standards.
- High elevation / Low cost.
- 100% inspection of section-by-section assembly.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for high-humidity coastal zones or industrial areas.
Physical Characteristics
- Maximum Axial Load: 500 kg.
- Height: 3 meters (1 section).
- Wind resistance: 200 km/hr.
- Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 1 | STZ45G | Tower section with 45 cm face width. |
| 1 | SCZ45G | 45 cm tower top with set screw for lightning rod. |
| 1 | SBZ45G | 45 cm tower base. |
| 1 | SAB45G | Anchor for 35/45 tower base. |
| 1 | SJB45G | Guy wire attachment bracket. |
| 3 | SAZ45G | Floor anchor for guy wire. |
| 6 | CUELLO-14-HDG | Thimble for guy wire. |
| 18 | NUDO-14-FJG | 1/4' wire rope clip. |
Does not include guy wire.
We recommend 20 meters of 1/4' guy wire (SRET-635-CAM) or larger diameters.
Does not include turnbuckles. We recommend 3 turnbuckles of 5/8' x 9' (TEN5/8X9OGJ or TEN5/8X9OQJ).
*Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy Wire Anchors is considered a forfeiture of the equipment warranty, and any additional modifications are the responsibility of the installer.
Complementary accessories (Not included)
Signaling/Lighting system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe type with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted in 7 bands of equal size: 4 in orange-red and 3 in white.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 5 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged wire rope clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
*NOM-009 mandates the use of systems to arrest accidental falls on a structure.
Recommended Grounding System for Tower and Equipment mounted on it (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity ground bus bar with insulators (no cabinet) |
* We recommend using 4 AWG coated copper wire (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, you can use 6 AWG (SLY-291-GRN).
Recommended Basic Lightning Protection System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning Rod Tip with Aluminum Mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp Electrode. Includes one bag of impedance improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic inspection box. |
| 1 | ANTIOX | Aerosol for terminal protection. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 2 | TGAC114 | Tower insulator. |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure the installation is performed by a trained professional.
- Schedule a maintenance plan for checking guy wire tension and tightening hardware.
- Do not install solar panels at a height of more than 6 meters. Check compatibility between solar cells and mounts.
- A stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white tones, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting).
- It is recommended to illuminate the tower at least at the tip with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images