3m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).

3m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).

Regular price $ 16,199.00
Regular price Sale price $ 16,199.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple Paga con tarjeta, Apple Pay o PayPal ¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096

Logo SYSCOM TOWERS

Key Features

  • Product manufactured under ISO 9001:2015 standards.
  • High elevation / Low cost.
  • 100% inspection of section-by-section assembly.
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
  • Ideal for high-humidity coastal zones or industrial areas.

Physical Characteristics

  • Maximum Axial Load: 500 kg.
  • Height: 3 meters (1 section).
  • Wind resistance: 200 km/hr.
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
  • Application: Outdoor (Humid zones).

Includes the following components

Quantity Model Description
1 STZ45G Tower section with 45 cm face width.
1 SCZ45G 45 cm tower top with set screw for lightning rod.
1 SBZ45G 45 cm tower base.
1 SAB45G Anchor for 35/45 tower base.
1 SJB45G Guy wire attachment bracket.
3 SAZ45G Floor anchor for guy wire.
6 CUELLO-14-HDG Thimble for guy wire.
18 NUDO-14-FJG 1/4' wire rope clip.

Does not include guy wire.

We recommend 20 meters of 1/4' guy wire (SRET-635-CAM) or larger diameters.

Does not include turnbuckles. We recommend 3 turnbuckles of 5/8' x 9' (TEN5/8X9OGJ or TEN5/8X9OQJ).

*Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy Wire Anchors is considered a forfeiture of the equipment warranty, and any additional modifications are the responsibility of the installer.

Complementary accessories (Not included)

Signaling/Lighting system (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe type with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mount for EIGSLSE obstruction light

*Signaling standards dictate that the tower must be painted in 7 bands of equal size: 4 in orange-red and 3 in white.

Lifeline system (Not included)

Quantity Model Description
1 SHE-LV Pair of mounting brackets
1 S-GULV Line guide
5 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged wire rope clip
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer.
1 SYS-USA7B (Optional) Suspension harness.

*NOM-009 mandates the use of systems to arrest accidental falls on a structure.

Recommended Grounding System for Tower and Equipment mounted on it (Not included)

Quantity Model Description
1 TG45AB 45 A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic access box.
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 1000A capacity ground bus bar with insulators (no cabinet)

* We recommend using 4 AWG coated copper wire (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, you can use 6 AWG (SLY-291-GRN).

Recommended Basic Lightning Protection System for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning Rod Tip with Aluminum Mast (MASTIL1.2)
1 TG45AB 45 Amp Electrode. Includes one bag of impedance improving compound (H2OHM), compass, and level.
1 S610 Small plastic inspection box.
1 ANTIOX Aerosol for terminal protection.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
2 TGAC114 Tower insulator.

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.

*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.

See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.

Recommendations

  • Ensure the installation is performed by a trained professional.
  • Schedule a maintenance plan for checking guy wire tension and tightening hardware.
  • Do not install solar panels at a height of more than 6 meters. Check compatibility between solar cells and mounts.
  • A stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
  • The tower must be painted in orange-red and white tones, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting).
  • It is recommended to illuminate the tower at least at the tip with a red lamp.

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram Version 2.0

Installation Images

Installation Image
View full details