Key Features
- Product manufactured under ISO 9001:2015 standards.
- High Elevation / Low cost.
- 100% Inspection of section-by-section assembly.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for coastal areas with high humidity or industrial zones.
Physical Characteristics
- Maximum Axial Load: 200 kg.
- Height: 3 meters (1 section).
- Wind resistance: 200 km/h.
- Anticorrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components
- 1 x STZ30G - 30 cm face width tower section.
- 1 x SCZ30PG - 30 cm tower top with lightning rod set screw.
- 1 x SBA30G - 30 cm tower base.
- 1 x SAB30G - Tower base anchor.
- 1 x SJB30G - Guy wire clamp.
- 1 x SAP02G - Floor anchor for guy wire.
- 3 x SAP02G - Floor anchor for guy wire.
- 6 x CUELLO-14-HDG - Thimble for guy wire.
- 18 x NUDO-316-FJG - 3/16" wire rope clip.
Complementary accessories
Does not include guy wire.
20 meters of 1/8" guy wire SRET-318-CAM or larger diameters are recommended.
Does not include turnbuckles.
3 turnbuckles of 1/2' x 6' are recommended. TEN1/2X6OGJ or TEN1/2X6OQJ.
**NOT using installation accessories such as clamps, tower base, tower anchor, or guy anchors is considered a forfeiture of the equipment warranty, and any additional adaptation is the responsibility of the installer.**
Signaling/Lighting System
- 2 x EIGSLSE - Autonomous LED strobe with photocell, solar panel, and battery. Type L810.
- 2 x HLU3R2 - Mounting bracket for EIGSLSE obstruction light.
*Signaling standards dictate that the tower must be painted in 7 stripes of equal size; 4 stripes in orange-red and 3 in white.
Lifeline System
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Recommended Grounding System for Tower and Mounted Equipment
- 1 x TG45AB - 45A grounding electrode with electrode, filter, and H2Ohm compound.
- 1 x S610 - Plastic inspection well.
- 3 x TGCR11 - Eye connector.
- 2 x TGAB18 - Rod connector.
- 1 x TGBUSG10 - 1000A capacity grounding busbar with insulators (without enclosure).
*Use of 4 AWG insulated copper cable SLY-287-GRN is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG SLY-291-GRN may be used.
Recommended Basic Lightning Protection System for Tower
- 1 x TGTDPC - Lightning rod with aluminum mast (MASTIL1.2).
- 1 x TG45AB - 45 Amp electrode. Includes a bag of impedance-improving compound (H2OHM), compass, and level.
- 1 x S610 - Small plastic inspection well.
- 1 x ANTIOX - Protective terminal spray.
- 3 x TGCR11 - Eye connector.
- 2 x TGAB18 - Rod connector.
- 2 x TGAC - Tower insulator.
*The dipole-type rod offers a 72° protection cone below the coil. Recommended for low-lightning-incidence areas.
*2/0 gauge copper cable SLY-346-BLK is recommended for integration. Assuming the electrode is installed a maximum of 3 meters from the tower, approximately 8 meters of cable are used.
New! Lightning Rod + Grounding Kit with Cable
KLP-TZ03-PRO - All included! Ideal for 3m towers with corona dipole, wiring, and electrodes.
Alternatively, you may quote the following Grounding or Lightning Rod components individually:
Recommendations
- Ensure installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at heights greater than 6 meters. Verify compatibility between solar cells and mounts.
- A structural stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending, leading to structural failure.
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting).
- It is recommended to light the tower at least at the tip with a red lamp.