Wishlist

3 m Ground-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section. (Guy wires not included).

  • $ 9,599.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-30G-003

Key Features Product manufactured under ISO 9001:2015 standards. High Elevation / Low cost. 100% Inspection of section-by-section assembly. Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008. Ideal for coastal areas with high...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30G-003 , supplier:Syscom , syscom

Key Features

  • Product manufactured under ISO 9001:2015 standards.
  • High Elevation / Low cost.
  • 100% Inspection of section-by-section assembly.
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
  • Ideal for coastal areas with high humidity or industrial zones.

Physical Characteristics

  • Maximum Axial Load: 200 kg.
  • Height: 3 meters (1 section).
  • Wind resistance: 200 km/h.
  • Anticorrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
  • Application: Outdoor (Humid zones).
Includes the following components
  • 1 x STZ30G - 30 cm face width tower section.
  • 1 x SCZ30PG - 30 cm tower top with lightning rod set screw.
  • 1 x SBA30G - 30 cm tower base.
  • 1 x SAB30G - Tower base anchor.
  • 1 x SJB30G - Guy wire clamp.
  • 1 x SAP02G - Floor anchor for guy wire.
  • 3 x SAP02G - Floor anchor for guy wire.
  • 6 x CUELLO-14-HDG - Thimble for guy wire.
  • 18 x NUDO-316-FJG - 3/16" wire rope clip.
Complementary accessories

Does not include guy wire.

20 meters of 1/8" guy wire SRET-318-CAM or larger diameters are recommended.

Does not include turnbuckles.

3 turnbuckles of 1/2' x 6' are recommended. TEN1/2X6OGJ or TEN1/2X6OQJ.

**NOT using installation accessories such as clamps, tower base, tower anchor, or guy anchors is considered a forfeiture of the equipment warranty, and any additional adaptation is the responsibility of the installer.**

Signaling/Lighting System
  • 2 x EIGSLSE - Autonomous LED strobe with photocell, solar panel, and battery. Type L810.
  • 2 x HLU3R2 - Mounting bracket for EIGSLSE obstruction light.

*Signaling standards dictate that the tower must be painted in 7 stripes of equal size; 4 stripes in orange-red and 3 in white.

Lifeline System

*NOM-009 mandates the use of systems that arrest accidental falls on a structure.

Recommended Grounding System for Tower and Mounted Equipment
  • 1 x TG45AB - 45A grounding electrode with electrode, filter, and H2Ohm compound.
  • 1 x S610 - Plastic inspection well.
  • 3 x TGCR11 - Eye connector.
  • 2 x TGAB18 - Rod connector.
  • 1 x TGBUSG10 - 1000A capacity grounding busbar with insulators (without enclosure).

*Use of 4 AWG insulated copper cable SLY-287-GRN is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG SLY-291-GRN may be used.

Recommended Basic Lightning Protection System for Tower
  • 1 x TGTDPC - Lightning rod with aluminum mast (MASTIL1.2).
  • 1 x TG45AB - 45 Amp electrode. Includes a bag of impedance-improving compound (H2OHM), compass, and level.
  • 1 x S610 - Small plastic inspection well.
  • 1 x ANTIOX - Protective terminal spray.
  • 3 x TGCR11 - Eye connector.
  • 2 x TGAB18 - Rod connector.
  • 2 x TGAC - Tower insulator.

*The dipole-type rod offers a 72° protection cone below the coil. Recommended for low-lightning-incidence areas.

*2/0 gauge copper cable SLY-346-BLK is recommended for integration. Assuming the electrode is installed a maximum of 3 meters from the tower, approximately 8 meters of cable are used.

New! Lightning Rod + Grounding Kit with Cable

KLP-TZ03-PRO - All included! Ideal for 3m towers with corona dipole, wiring, and electrodes.

Alternatively, you may quote the following Grounding or Lightning Rod components individually:

Recommendations
  • Ensure installation is performed by a trained professional.
  • Schedule a maintenance plan to check guy wire tension and tighten hardware.
  • Do not install solar panels at heights greater than 6 meters. Verify compatibility between solar cells and mounts.
  • A structural stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending, leading to structural failure.
  • The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting).
  • It is recommended to light the tower at least at the tip with a red lamp.

Recently viewed