SYSCOM TOWERS
30m Guyed Tower Kit for Ground Installation with STZ30 Electro-Galvanized Section (Guy wires not included).
30m Guyed Tower Kit for Ground Installation with STZ30 Electro-Galvanized Section (Guy wires not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standards.
- High elevation / Low cost.
- 100% section-by-section assembly inspection.
- Electrolytic galvanization according to ASTM B-633 standards.
- Ideal for dry, corrosion-free areas.
Physical Characteristics
- Maximum Axial Load: 200 kg.
- Height: 30 meters (10 sections).
- Wind Resistance: 200 km/hr.
- Anti-corrosion protection: Electrolytic Galvanization (ASTM B-633).
- Application: Outdoor (Desert or low-humidity areas).
- 10 units: STZ30 - 30 cm face width tower section
- 1 unit: SCZ30P - 30 cm tower top cap with set screw for lightning rod
- 1 unit: SBA30 - Base for 30 cm tower
- 1 unit: SAB30 - Tower base anchor
- 5 units: SJB30 - Guy wire clamp flange
- 3 units: SAP02 - Floor anchor for guy wire
- 30 units: CUELLO-14-HDG - Thimble for guy cable
- 90 units: NUDO-316-FJG - 3/16' wire rope clip
Guy cable not included. 480 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.
Turnbuckles not included. 15 1/2' x 6' turnbuckles (TEN1/2X6OGJ or TEN1/2X6OQJ) are recommended.
**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy anchors is considered a forfeiture of the equipment warranty, and any additional modifications are the responsibility of the installer.**
Signaling/Lighting System (Not included)
- 2 units: EIGSLSE - Autonomous LED strobe with photocell, solar panel, and battery. Type L810
- 2 units: HLU3R2 - Mount for EIGSLSE obstruction light
*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 in orange-red and 3 in white.
- 1 unit: SHE-LV - Pair of mounting brackets
- 1 unit: S-GULV - Line guide
- 33 units: SRET-338CAM - 3/8' cable
- 2 units: CUELLO-38-HDG - 3/8' thimble
- 1 unit: TRY-ACC-SLIDER - Safety Slider for installer (Optional)
- 1 unit: SYS-USA7B - Suspension harness (Optional)
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
KLP-TZ30-PRO - Everything included! Ideal for 30m towers with corona dipole, wiring, and electrodes.
Alternatively, you may individually quote the following Grounding or Lightning Rod components:
- 1 unit: TG45AB - 45A grounding electrode with electrode, filter, and H2Ohm compound
- 1 unit: S610 - Plastic inspection well
- 3 units: TGCR11 - Eye connector
- 2 units: TGAB18 - Rod connector
- 1 unit: TGBUSG10 - 1000A capacity ground bus bar with insulators (without cabinet)
*Use of 4 AWG coated copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. For tower equipment, 6 AWG (SLY-291-GRN) can be used.
- 1 unit: TGTDPC - Lightning rod tip with aluminum mast (MASTIL1.2)
- 1 unit: TG45AB - 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level.
- 1 unit: S610 - Small plastic inspection well
- 1 unit: ANTIOX - Spray for terminal protection
- 3 units: TGCR11 - Eye connector
- 2 units: TGAB18 - Rod connector
- 20 units: TGAC - Tower insulator
*The dipole tip offers a 72° protection cone below the coil. Recommended for low lightning incidence areas.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering a maximum electrode installation distance of 3 meters from the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure installation is performed by a trained professional.
- Schedule a maintenance plan to check guy tensions and tighten hardware.
- Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts.
- A structural stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white, in 7 equal-height bands starting and ending with orange-red (SYSCOM does not perform tower painting).
- It is recommended to light the tower at least at the tip with a red lamp.
Representative Diagram: Guy wire installation Version 2.0
Installation images