30 m Ground-Mounted Guyed Tower Kit with STZ35 Electro-Galvanized Section (Guy wires not included).

  • $ 43,799.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-35E-030

Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% section-by-section assembly inspection Electrolytic galvanization according to ASTM B-633 standards. Ideal for dry, corrosion-free areas Physical...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35E-030 , supplier:Syscom , syscom

SYSCOM TOWERS Logo

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost
  • 100% section-by-section assembly inspection
  • Electrolytic galvanization according to ASTM B-633 standards.
  • Ideal for dry, corrosion-free areas

Physical Characteristics

  • Maximum Axial Load: 350 kg
  • Height: 30 meters (10 sections)
  • Wind Resistance: 200 km/hr
  • Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
  • Application: Outdoor (desert or low humidity areas)

Includes the following components

Quantity Model Description
10 STZ35 Tower section with 35 cm face width.
1 SCZ35P 35 cm tower top cap with lightning rod clamp.
1 SBZ35 Base for 35 cm tower.
1 SAB45 Anchor for 35/45 tower base.
4 SJB35 Guy wire support bracket.
3 SAZ45 Floor anchor for guy wire.
24 CUELLO-14-HDG Thimble for guy wire
72 NUDO-316-FJG 3/16" wire rope clip.

Guy wire not included. 385 meters of 3/16" guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.

Turnbuckles not included. 12 units of 5/8" x 9" turnbuckles are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).

**Failure to use installation accessories such as brackets, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the sole responsibility of the installer.**

Complementary Accessories (Not included)

Signaling/Lighting System (Not included):

Quantity Model Description
2 EIGSLSE Self-contained LED strobe with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mounting bracket for EIGSLSE obstruction light.

*Signaling standards dictate that the tower must be painted in 7 alternating stripes of equal size: 4 aviation orange and 3 white.

Lifeline System (Not included):

Quantity Model Description
1 SHE-LV Pair of support fittings.
2 S-GULV Line guide.
33 SRET-338CAM 3/8" cable.
6 NUDO-38FJG 3/8" forged clip.
2 CUELLO-38-HDG 3/8" thimble.
1 TRY-ACC-SLIDER (Optional) Safety slider for installer.
1 SYS-USA7B (Optional) Suspension harness.

*NOM-009 mandates the use of systems to arrest accidental falls on a structure.

Recommended Grounding System for Tower and Mounted Equipment (Not included)

Quantity Model Description
1 TG45AB 45A grounding electrode with electrode, filter, and H2Ohm compound.
1 S610 Plastic access box.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
1 TGBUSG10 1000A capacity ground bus bar with insulators (without cabinet).

* The use of 4 AWG copper-clad grounding wire (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Recommended Basic Lightning Protection System for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod with aluminum mast (MASTIL1.2).
1 TG45AB 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass, and level.
1 S610 Small plastic access box.
1 ANTIOX Anti-oxidation spray for terminal protection.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
20 TGAC114 Tower insulator.

*The dipole tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.

See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM

Recommendations

  • Ensure that the installation is performed by a trained professional.
  • Schedule a maintenance plan to check guy wire tension and tighten hardware.
  • Do not install solar panels at a height greater than 6 meters. Check the compatibility between solar cells and mounts.
  • A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
  • The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting).
  • It is recommended to illuminate the tower at least at the tip with a red lamp.

Representative Diagram: Guy Wire Installation Version 2.0