30 m Ground-Mounted Guyed Tower Kit with STZ35 Electro-Galvanized Section (Guy wires not included).
- $ 43,799.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: KTZ-35E-030
Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% section-by-section assembly inspection Electrolytic galvanization according to ASTM B-633 standards. Ideal for dry, corrosion-free areas Physical...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35E-030 , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standards
- High elevation / Low cost
- 100% section-by-section assembly inspection
- Electrolytic galvanization according to ASTM B-633 standards.
- Ideal for dry, corrosion-free areas
Physical Characteristics
- Maximum Axial Load: 350 kg
- Height: 30 meters (10 sections)
- Wind Resistance: 200 km/hr
- Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
- Application: Outdoor (desert or low humidity areas)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 10 | STZ35 | Tower section with 35 cm face width. |
| 1 | SCZ35P | 35 cm tower top cap with lightning rod clamp. |
| 1 | SBZ35 | Base for 35 cm tower. |
| 1 | SAB45 | Anchor for 35/45 tower base. |
| 4 | SJB35 | Guy wire support bracket. |
| 3 | SAZ45 | Floor anchor for guy wire. |
| 24 | CUELLO-14-HDG | Thimble for guy wire |
| 72 | NUDO-316-FJG | 3/16" wire rope clip. |
Guy wire not included. 385 meters of 3/16" guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Turnbuckles not included. 12 units of 5/8" x 9" turnbuckles are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
**Failure to use installation accessories such as brackets, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the sole responsibility of the installer.**
Complementary Accessories (Not included)
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Self-contained LED strobe with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mounting bracket for EIGSLSE obstruction light. |
*Signaling standards dictate that the tower must be painted in 7 alternating stripes of equal size: 4 aviation orange and 3 white.
Lifeline System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of support fittings. |
| 2 | S-GULV | Line guide. |
| 33 | SRET-338CAM | 3/8" cable. |
| 6 | NUDO-38FJG | 3/8" forged clip. |
| 2 | CUELLO-38-HDG | 3/8" thimble. |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
*NOM-009 mandates the use of systems to arrest accidental falls on a structure.
Recommended Grounding System for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound. |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 1 | TGBUSG10 | 1000A capacity ground bus bar with insulators (without cabinet). |
* The use of 4 AWG copper-clad grounding wire (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Protection System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod with aluminum mast (MASTIL1.2). |
| 1 | TG45AB | 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic access box. |
| 1 | ANTIOX | Anti-oxidation spray for terminal protection. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 20 | TGAC114 | Tower insulator. |
*The dipole tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM
Recommendations
- Ensure that the installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height greater than 6 meters. Check the compatibility between solar cells and mounts.
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting).
- It is recommended to illuminate the tower at least at the tip with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images