30 m Self-Supporting Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).
- $ 54,899.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: KTZ-35G-030
Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% section-by-section assembly inspection Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008 Ideal for high-humidity coastal zones or industrial...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35G-030 , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standards
- High elevation / Low cost
- 100% section-by-section assembly inspection
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
- Ideal for high-humidity coastal zones or industrial areas
Physical Characteristics
- Maximum Axial Load: 350 kg
- Height: 30 meters (10 sections)
- Wind resistance: 200 km/h
- Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 10 | STZ35G | Tower section with 35 cm face width |
| 1 | SCZ35PG | 35 cm tower top with lightning rod set screw |
| 1 | SBZ35G | 35 cm tower base |
| 1 | SAB45G | Anchor for 35/45 tower base |
| 4 | SJB35G | Guy wire support flange |
| 3 | SAZ45G | Floor anchor for guy wire |
| 24 | CUELLO-14-HDG | Thimble for guy wire |
| 72 | NUDO-316-FJG | 3/16' wire rope clip |
Does not include guy wire. 385 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Does not include turnbuckles. 12 5/8' x 9' turnbuckles are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will result in the loss of the equipment warranty, and any additional modifications are the responsibility of the installer.
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
* The signaling standard dictates that the tower must be painted in 7 bands of equal size; 4 orange-red bands and 3 white bands.
Lifeline System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 2 | S-GULV | Line guide |
| 33 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | Forged 3/8' clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
* NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Grounding System Recommended for Tower and Equipment mounted on it (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Grounding bar with 1000A capacity insulators (No cabinet) |
* The use of 4 AWG coated copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With one bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection box |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye terminal connector |
| 2 | TGAB18 | Ground rod connector |
| 20 | TGAC114 | Tower insulator |
*The dipole tip offers a 72° cone of protection below the coil. Recommended for areas with low lightning incidence
*2/0 gauge copper cable is recommended for the integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used
See the physical ground + lightning rod connection diagram in the following DIAGRAM
Recommendations
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and tightening hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting work)
- It is recommended to light the tower at least at the tip with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images