Wishlist

30 m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).

  • $ 68,299.00
  • Brand: SYSCOM TOWERS
  • Availability: 5 In stock
  • SKU: KTZ-45G-030

Key Features Product manufactured under ISO 9001:2015 standards Great Elevation / Low cost 100% Section-by-Section Assembly Inspection Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008 Ideal for high-humidity coastal zones or industrial...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-45G-030 , supplier:Syscom , syscom

Logo SYSCOM TOWERS

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • Great Elevation / Low cost
  • 100% Section-by-Section Assembly Inspection
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal zones or industrial areas

Physical Characteristics

  • Maximum Axial Load: 500 kg
  • Height: 30 meters (10 sections)
  • Wind resistance: 200 km/h
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
  • Application: Outdoor (Humid Zones)

Includes the following components

Quantity Model Description
10 STZ45G Tower section with 45 cm face width
1 SCZ45G 45 cm tower top cap with lightning rod set screw
1 SBZ45G Base for 45 cm tower
1 SAB45G Anchor for 35/45 tower base
4 SJB45G Guy wire bracket
3 SAZ45G Floor anchor for guy wire
24 CUELLO-14-HDG Thimble for guy wire
72 NUDO-14-FJG 1/4' wire rope clip

Guy wire not included. 385 meters of 1/4' guy wire (SRET-635-CAM) or larger diameters are recommended.

Turnbuckles not included. 12 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).

**Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy wire Anchors is considered a voiding of the equipment warranty, and any additional adaptation is the sole responsibility of the installer.**


Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. Type L810
2 HLU3R2 Mount for EIGSLSE obstruction light

* Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 bands in orange-red and 3 in white.

Lifeline System (Not included)

Quantity Model Description
1 SHE-LV Pair of mounting brackets
2 S-GULV Line guide
33 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged rope clip
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer
1 SYS-USA7B (Optional) Suspension Harness

* NOM-009 mandates the use of systems to arrest accidental falls on a structure.

Recommended Grounding System for Tower and Mounted Equipment (Not included)

Quantity Model Description
1 TG45AB 45 A grounding electrode with Electrode, Filter, and H2Ohm compound
1 S610 Plastic access box
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 1000A capacity ground bus bar with insulators (No cabinet)

* Use of 4 AWG insulated copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG cable (SLY-291-GRN) can be used.

Basic Lightning Protection System Recommended for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass, and level
1 S610 Small plastic inspection well
1 ANTIOX Terminal protection spray
3 TGCR11 Eye connector
2 TGAB18 Rod connector
20 TGAC114 Tower insulator

*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.

*2/0 gauge copper cable is recommended for the integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.

See the Grounding + Lightning Rod connection diagram in the following DIAGRAM


Recommendations

  • Ensure that the installation is performed by a trained professional
  • Schedule a maintenance plan to check guy wire tension and tighten hardware
  • Do not install solar panels at a height of more than 6 meters. Check compatibility between solar cells and mounts
  • A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform the tower painting work)
  • It is recommended to illuminate the tower at least at the tip with a red lamp

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram

Installation Images

Installation Image

Recently viewed