33 m Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).
- $ 73,499.00
- Brand: SYSCOM TOWERS
- Availability: 4 In stock
- SKU: KTZ-45G-033
Key Features: Product manufactured under ISO 9001:2015 standards. High Elevation / Low cost. 100% Section-by-section assembly inspection. Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008. Ideal for high-humidity coastal areas or industrial...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-45G-033 , supplier:Syscom , syscom
Key Features:
- Product manufactured under ISO 9001:2015 standards.
- High Elevation / Low cost.
- 100% Section-by-section assembly inspection.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for high-humidity coastal areas or industrial zones.
Physical Characteristics:
- Maximum Axial Load: 500 kg.
- Height: 33 meters (11 sections).
- Wind resistance: 200 km/h.
- Anticorrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components:
| Quantity | Model | Description |
|---|---|---|
| 11 | STZ45G | 45 cm face width tower section. |
| 1 | SCZ45G | 45 cm tower top with set screw for lightning rod. |
| 1 | SBZ45G | 45 cm tower base. |
| 1 | SAB45G | 35/45 tower base anchor. |
| 4 | SJB45G | Guy wire clamp. |
| 3 | SAZ45G | Ground anchor for guy wire. |
| 24 | CUELLO-14-HDG | Thimble for guy wire |
| 72 | NUDO-14-FJG | 1/4" wire rope clip. |
Guy wire not included. 420 meters of 1/4" guy wire (SRET-635-CAM) or larger diameters are recommended.
Turnbuckles not included. 12 turnbuckles 5/8" x 9" are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
Failure to use installation accessories such as clamps, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the responsibility of the installer.
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
*The signaling standard dictates that the tower must be painted with 7 equal-sized bands; 4 reddish-orange bands and 3 white bands.
Lifeline system (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 2 | S-GULV | Line guide |
| 36 | SRET-338CAM | 3/8" cable |
| 6 | NUDO-38FJG | 3/8" forged rope clip |
| 2 | CUELLO-38-HDG | 3/8" thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer. |
| 1 | SYS-USA7B | (Optional) Full body harness. |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Grounding system recommended for the tower and equipment mounted on it (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity busbar with insulators (without cabinet) |
* It is recommended to use 4 AWG coated copper cable (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic lightning protection system recommended for the tower (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With one bag of impedance-improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic access box. |
| 1 | ANTIOX | Terminal protection spray. |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations:
- Ensure the installation is carried out by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height of more than 6 meters. Check compatibility between solar cells and mounts.
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not provide tower painting services).
- It is recommended to illuminate the tower, at least at the tip, with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images