36 m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).

  • $ 78,799.00
  • Brand: SYSCOM TOWERS
  • Availability: 4 In stock
  • SKU: KTZ-45G-036

Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost. 100% inspection of section-by-section assembly. Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008 Ideal for coastal areas with high...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-45G-036 , supplier:Syscom , syscom

Logo SYSCOM TOWERS

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost.
  • 100% inspection of section-by-section assembly.
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
  • Ideal for coastal areas with high humidity or industrial zones.

Physical Characteristics

  • Maximum Axial Load: 500 kg.
  • Height: 36 meters (12 sections).
  • Wind resistance: 200 km/h.
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
  • Application: Outdoor (Humid Areas).
Includes the following components:
Quantity Model Description
12 STZ45G Tower section, 45 cm face width.
1 SCZ45G Tower top, 45 cm, with lightning rod set screw.
1 SBZ45G Base for 45 cm tower.
1 SAB45G Anchor for 35/45 tower base.
4 SJB45G Guy wire attachment bracket.
3 SAZ45G Ground anchor for guy wire.
24 CUELLO-14-HDG Guy wire thimble
72 NUDO-14-FJG 1/4" wire rope clip
Recommended Accessories (Not included)
  • Guy wire: 450 meters of 1/4" guy wire (SRET-635-CAM) or larger diameters are recommended. SRET-635-CAM
  • Turnbuckles: 12 5/8" x 9" turnbuckles are recommended. TEN5/8X9OGJ or TEN5/8X9OQJ
  • Warning: Using non-standard accessories voids the equipment warranty

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mount for EIGSLSE obstruction light

* Signaling standards dictate that the tower must be painted in 7 alternating stripes of equal size; 4 orange-red and 3 white.

Lifeline System (Not included)

Quantity Model Description
1 SHE-LV Pair of mounting brackets
2 S-GULV Line guide
39 SRET-338CAM 3/8" cable
6 NUDO-38FJG 3/8" forged wire rope clip
2 CUELLO-38-HDG 3/8" thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer.
1 SYS-USA7B (Optional) Suspension harness.

* NOM-009 mandates the use of fall arrest systems when working on a structure.

Recommended Grounding System (Not included)

Quantity Model Description
1 TG45AB 45A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic inspection pit.
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 Grounding bus bar with 1000A capacity insulators (no cabinet)

* It is recommended to use 4 AWG insulated copper wire SLY-287-GRN for grounding the electrode to the tower. For equipment on the tower, 6 AWG SLY-291-GRN can be used.

Recommended Basic Lightning Protection System (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp. electrode with one bag of impedance improvement compound (H2OHM), compass, and level.
1 S610 Small plastic inspection pit.
1 ANTIOX Terminal protection spray.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
24 TGAC114 Tower insulator.

*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 AWG copper wire is recommended for integration SLY-346-BLK. Assuming the electrode is installed at a maximum of 3 meters from the tower, approximately 8 meters are needed.

See the Grounding + Lightning rod connection diagram in the following DIAGRAM.


Recommendations

  • Ensure the installation is performed by a trained professional.
  • Schedule a maintenance plan to check guy wire tension and tighten hardware.
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
  • A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
  • The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting).
  • It is recommended to light the tower at least at the top with a red lamp.