Skip to product information
1 of 1

SYSCOM TOWERS

39 m Floor-Mounted Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wires not included).

39 m Floor-Mounted Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wires not included).

Regular price $ 68,399.00
Regular price Sale price $ 68,399.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple Paga con tarjeta, Apple Pay o PayPal ¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096

Logo SYSCOM TOWERS

Highlighted Features

  • Product manufactured under ISO 9001:2015 standard
  • High Elevation / Low cost
  • 100% Inspection of section-by-section assembly
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal zones or industrial areas

Physical Characteristics

  • Maximum Axial Load: 350 kg
  • Height: 39 meters (13 sections)
  • Wind resistance: 200 km/h
  • Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
  • Application: Outdoors (Humid zones)

Includes the following components

Quantity Model Description
13 STZ35G Tower section with 35 cm face width
1 SCZ35PG 35 cm tower top with set screw for lightning rod
1 SBZ35G Base for 35 cm tower
1 SAB45G Anchor for 35/45 tower base
5 SJB35G Guy wire clamp flange
3 SAZ45G Floor anchor for guy wire
30 CUELLO-14-HDG Thimble for guy cable
90 NUDO-316-FJG 3/16' cable clamp

Guy cable not included.

We recommend 600 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters.

Turnbuckles not included.

We recommend 15 turnbuckles of 5/8' x 9'. (TEN5/8X9OGJ or TEN5/8X9OQJ).

**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will be considered a voidance of the equipment warranty, and any additional modifications remain the responsibility of the installer.**


Complementary accessories (Not included)

Signaling/Lighting System (Not included):

Quantity Model Description
2 EIGSLSE Self-contained LED strobe with photocell, solar panel, and battery. Type L810
2 HLU3R2 Mounting for EIGSLSE obstruction light

*Signaling standards dictate that the tower must be painted with 7 equal-sized bands; 4 in reddish-orange and 3 in white.

Lifeline System (Not included):

Quantity Model Description
1 SHE-LV Pair of mounting brackets
2 S-GULV Line guide
42 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged clamp
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety Slider for Installer
1 SYS-USA7B (Optional) Suspension Harness

*NOM-009 mandates the use of systems to arrest accidental falls on a structure.


Grounding System Recommended for Tower and Mounted Equipment (Not included)

Quantity Model Description
1 TG45AB 45 A grounding electrode with Electrode, Filter, and H2Ohm compound
1 S610 Plastic inspection housing
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 Bonding bar with insulators, 1000A capacity (No enclosure)

* It is recommended to use 4 AWG coated copper cable (SLY-287-GRN) for electrode grounding up to the tower. For tower equipment, 6 AWG can be used (SLY-291-GRN).


Basic Lightning Protection System Recommended for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp electrode with one bag of impedance-improving compound (H2OHM), compass, and level
1 S610 Small plastic inspection housing
1 ANTIOX Aerosol for terminal protection
3 TGCR11 Eye Connector
2 TGAB18 Rod Connector

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.

2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.


Recommendations

  • Ensure the installation is performed by a trained professional
  • Schedule a maintenance plan to check guy wire tension and tighten hardware
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
  • A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting work)
  • It is recommended to illuminate the tower at least at the top with a red lamp

Representative Diagram: Guy Wire Installation Version 2.0

Guy wire installation diagram Version 2.0

Installation Images

Installation images

See the Grounding + Lightning Rod connection diagram in the following DIAGRAM

View full details