SYSCOM TOWERS
39 m Floor-Mounted Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wires not included).
39 m Floor-Mounted Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wires not included).
Couldn't load pickup availability
Highlighted Features
- Product manufactured under ISO 9001:2015 standard
- High Elevation / Low cost
- 100% Inspection of section-by-section assembly
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
- Ideal for high-humidity coastal zones or industrial areas
Physical Characteristics
- Maximum Axial Load: 350 kg
- Height: 39 meters (13 sections)
- Wind resistance: 200 km/h
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoors (Humid zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 13 | STZ35G | Tower section with 35 cm face width |
| 1 | SCZ35PG | 35 cm tower top with set screw for lightning rod |
| 1 | SBZ35G | Base for 35 cm tower |
| 1 | SAB45G | Anchor for 35/45 tower base |
| 5 | SJB35G | Guy wire clamp flange |
| 3 | SAZ45G | Floor anchor for guy wire |
| 30 | CUELLO-14-HDG | Thimble for guy cable |
| 90 | NUDO-316-FJG | 3/16' cable clamp |
Guy cable not included.
We recommend 600 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters.
Turnbuckles not included.
We recommend 15 turnbuckles of 5/8' x 9'. (TEN5/8X9OGJ or TEN5/8X9OQJ).
**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will be considered a voidance of the equipment warranty, and any additional modifications remain the responsibility of the installer.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Self-contained LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted with 7 equal-sized bands; 4 in reddish-orange and 3 in white.
Lifeline System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 2 | S-GULV | Line guide |
| 42 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety Slider for Installer |
| 1 | SYS-USA7B | (Optional) Suspension Harness |
*NOM-009 mandates the use of systems to arrest accidental falls on a structure.
Grounding System Recommended for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic inspection housing |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Bonding bar with insulators, 1000A capacity (No enclosure) |
* It is recommended to use 4 AWG coated copper cable (SLY-287-GRN) for electrode grounding up to the tower. For tower equipment, 6 AWG can be used (SLY-291-GRN).
Basic Lightning Protection System Recommended for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode with one bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection housing |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye Connector |
| 2 | TGAB18 | Rod Connector |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting work)
- It is recommended to illuminate the tower at least at the top with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM