Skip to product information
1 of 1

SYSCOM TOWERS

39 m Height Guyed Floor Tower Kit with Hot-Dip Galvanized STZ45G Section. (Guy wires not included).

39 m Height Guyed Floor Tower Kit with Hot-Dip Galvanized STZ45G Section. (Guy wires not included).

Regular price $ 85,599.00
Regular price Sale price $ 85,599.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple Paga con tarjeta, Apple Pay o PayPal ¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096

SYSCOM TOWERS Logo

Key Features:

  • Product manufactured under ISO 9001:2015 standards.
  • High elevation / Low cost.
  • 100% inspection of section-by-section assembly.
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
  • Ideal for high-humidity coastal zones or industrial areas.

Physical Specifications:

  • Maximum Axial Load: 500 kg.
  • Height: 39 meters (13 sections).
  • Wind resistance: 200 km/hr.
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
  • Application: Outdoor (Humid zones).
Includes the following components:
  • 13 - STZ45G: 45 cm face width tower section.
  • 1 - SCZ45G: 45 cm tower top cap with lightning rod clamp.
  • 1 - SBZ45G: Base for 45 cm tower.
  • 1 - SAB45G: Anchor for 35/45 tower base.
  • 5 - SJB45G: Guy wire clamp.
  • 3 - SAZ45G: Floor anchor for guy wire.
  • 30 - CUELLO-14-HDG: Thimble for guy wire.
  • 90 - NUDO-14-FJG: 1/4' wire rope clip.
Recommended accessories

Guy wire is not included. We recommend 600 meters of 1/4' guy wire (SRET-635-CAM) or larger diameters.

Turnbuckles are not included. We recommend 15 turnbuckles of 5/8' x 9' (TEN5/8X9OGJ or TEN5/8X9OQJ).

*Failure to use installation accessories such as clamps, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the responsibility of the installer.


Signaling/Lighting System (Not included)
  • 2 - EIGSLSE: Autonomous LED strobe with photocell, solar panel, and battery. Type L810.
  • 2 - HLU3R2: Mounting for EIGSLSE obstruction light.

*Signaling standards dictate that the tower must be painted in 7 alternating bands of equal size; 4 orange-red bands and 3 white bands.

Lifeline System (Not included)

*NOM-009 requires the use of systems that arrest accidental falls from a structure.

Recommended Grounding System for Tower and Mounted Equipment (Not included)
  • 1 - TG45AB: 45A grounding electrode with filter and H2Ohm compound.
  • 1 - S610: Plastic inspection well.
  • TGCR11: Eye connector.
  • 2 - TGAB18: Rod connector.
  • 1 - TGBUSG10: 1000A capacity grounding busbar (no cabinet).

*We recommend 4 AWG jacketed copper wire (SLY-287-GRN) for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.


Recommended Basic Lightning Protection System for Tower (Not included)
  • 1 - TGTDPC: Lightning rod tip with aluminum mast (MASTIL1.2).
  • 1 - TG45AB: 45 Amp electrode with impedance-improving compound (H2OHM), compass, and level.
  • 1 - S610: Small plastic inspection well.
  • 1 - ANTIOX: Protective spray for terminals.
  • 3 - TGCR11: Eye connector.
  • 2 - TGAB18: Rod connector.
  • 26 - TGAC114: Tower insulator.

*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*We recommend 2/0 gauge copper wire for integration (SLY-346-BLK). Assuming the electrode is installed at a maximum of 3 meters from the tower, approx. 8 meters are used.

View Grounding + Lightning Protection connection diagram: DIAGRAM


Recommendations:

  • Ensure installation is performed by a trained professional.
  • Establish a maintenance plan for checking guy wire tension and hardware tightening.
  • Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts.
  • A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive twisting and bending, leading to structural failure.
  • The tower must be painted orange-red and white, in 7 bands of equal height, starting and ending with orange-red (SYSCOM does not perform painting).
  • It is recommended to illuminate the tower at the top with at least one red lamp.

Representative Diagram: Guy Wire Installation Version 2.0

Guy wire installation diagram

Installation Images

Guyed Tower Installation
View full details