Wishlist

42 m Floor-Mounted Guyed Tower Kit with Galvanized STZ35 Section (Guy wires not included).

  • $ 57,799.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-35E-042

Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% section-by-section assembly inspection Electrolytic galvanization according to ASTM B-633 standards Ideal for dry, corrosion-free areas Physical...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35E-042 , supplier:Syscom , syscom

Logo SYSCOM TOWERS

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost
  • 100% section-by-section assembly inspection
  • Electrolytic galvanization according to ASTM B-633 standards
  • Ideal for dry, corrosion-free areas

Physical Characteristics

  • Maximum Axial Load: 350 kg
  • Height: 42 meters (14 sections)
  • Wind Resistance: 200 km/hr
  • Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
  • Application: Outdoor (Desert areas or low humidity)

Includes the following components

Quantity Model Description
14 STZ35 35 cm face width tower section
1 SCZ35P 35 cm tower top with lightning rod clamp
1 SBZ35 35 cm tower base
1 SAB45 Anchor for 35/45 tower base
5 SJB35 Guy wire support clamp
3 SAZ45 Floor anchor for guy wire
30 CUELLO-14-HDG Thimble for guy wire
90 NUDO-316-FJG 3/16" wire rope clip

Guy wire not included. We recommend 650 meters of 3/16" guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters.

Turnbuckles not included. We recommend 15 turnbuckles of 5/8" x 9" (TEN5/8X9OGJ or TEN5/8X9OQJ).

**Failure to use installation accessories such as clamps, tower base, tower anchor, or guy wire anchors will be considered a voiding of the equipment warranty, and any additional adaptation is the responsibility of the installer.**

Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe light with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mounting for EIGSLSE obstruction light.

*Signaling standards dictate that the tower must be painted in 7 stripes of equal size; 4 orange-red stripes and 3 white stripes.

Lifeline system (Not included)

Quantity Model Description
1 SHE-LV Pair of mounting brackets.
2 S-GULV Guide for lifeline.
45 SRET-338CAM 3/8" cable.
6 NUDO-38FJG 3/8" forged clip.
2 CUELLO-38-HDG 3/8" thimble.
1 TRY-ACC-SLIDER (Optional) Safety slider for installer.
1 SYS-USA7B (Optional) Suspension harness.

*NOM-009 mandates the use of systems that prevent accidental falls on a structure.

Recommended Grounding System for Tower and Mounted Equipment (Not included)

Quantity Model Description
1 TG45AB 45A grounding electrode with electrode, filter, and H2Ohm compound.
1 S610 Plastic access box.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
1 TGBUSG10 Ground bus bar with 1000A capacity insulators (No cabinet).

* We recommend using 4 AWG coated copper wire (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Recommended Basic Lightning Protection System for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod with aluminum mast (MASTIL1.2).
1 TG45AB 45 Amp electrode. With one bag of impedance-improving compound (H2OHM), compass, and level.
1 S610
Small plastic inspection box 1 ANTIOX Aerosol for terminal protection 3 TGCR11 Eye terminal connector 2 TGAB18 Rod connector 28 TGAC114 Tower insulator

*The dipole-type tip provides a 72° cone of protection below the coil. It is recommended for areas with low lightning incidence

*A 2/0 AWG copper cable is recommended for the integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used

See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM

Recommendations

  • Ensure that the installation is performed by a trained professional
  • Schedule a maintenance plan to check guy wire tension and tighten hardware
  • Do not install solar panels at a height greater than 6 meters. Check the compatibility between solar cells and mounts
  • A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting work)
  • It is recommended to light the tower at least at the top with a red lamp

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram

Installation Images

Installation Images

Recently viewed