SYSCOM TOWERS
42m Floor-Mounted Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wires not included).
42m Floor-Mounted Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wires not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standards.
- High elevation / Low cost.
- 100% section-by-section assembly inspection.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for high-humidity coastal zones or industrial areas.
Physical Characteristics
- Maximum Axial Load: 350 kg.
- Height: 42 meters (14 sections).
- Wind resistance: 200 km/h.
- Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoors (Humid zones).
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 14 | STZ35G | 35 cm face width tower section. |
| 1 | SCZ35PG | 35 cm tower top cap with lightning rod clamp. |
| 1 | SBZ35G | Base for 35 cm tower. |
| 1 | SAB45G | Anchor for 35/45 tower base. |
| 5 | SJB35G | Guy wire clamp. |
| 3 | SAZ45G | Floor anchor for guy wire. |
| 30 | CUELLO-14-HDG | Thimble for guy wire |
| 90 | NUDO-316-FJG | 3/16' cable clamp. |
Guy wire not included.
We recommend 650 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters.
Turnbuckles not included
We recommend 15 5/8' x 9' turnbuckles. (TEN5/8X9OGJ or TEN5/8X9OQJ).
*Failure to use installation accessories such as clamps, tower base, tower anchor, or guy wire anchors will void the equipment warranty, and any additional modifications are the responsibility of the installer.
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. L810 type. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction lamp |
*Signaling regulations dictate that the tower must be painted in 7 strips of equal size; 4 strips in reddish-orange and 3 in white.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 2 | S-GULV | Line guide |
| 45 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety carriage for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Recommended Physical Grounding System for Tower and Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with Electrode, Filter, and H2Ohm Compound |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity connection bar with insulators (Without cabinet) |
* Use of 4 AWG insulated copper cable (SLY-287-GRN) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG cable (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included)
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
View Physical Grounding + Lightning Rod connection diagram
Recommendations
- Ensure that the installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive twisting and bending in the tower, leading to structural failures.
- The tower must be painted in orange-red and white tones, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting).
- It is recommended to illuminate the tower, at least at the top, with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0