45 m Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wires not included).
45 m Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wires not included).
Couldn't load pickup availability

Highlighted Features:
- Product manufactured Under ISO 9001:2015 Standard.
- High Elevation / Low cost.
- 100% Section-by-Section Assembly Inspection.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for high-humidity coastal areas or industrial zones.
Physical Characteristics:
- Maximum Axial Load: 350 Kg.
- Height: 45 meters (15 sections).
- Wind resistance: 200 km/hr.
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoors (Humid Zones).
Includes the following components:
| Quantity | Model | Description |
|---|---|---|
| 15 | STZ35G | Tower section, 35 cm face width. |
| 1 | SCZ35PG | Tower top, 35 cm, with lightning rod clamp. |
| 1 | SBZ35G | Tower base, 35 cm. |
| 1 | SAB45G | Tower base anchor, 35/45. |
| 5 | SJB35G | Guy wire mounting bracket. |
| 3 | SAZ45G | Ground anchor for guy wire. |
| 30 | CUELLO-14-HDG | Thimble for guy wire. |
| 90 | NUDO-316-FJG | 3/16" wire rope clip. |
Does not include guy wire. 685 meters of 3/16" guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Does not include turnbuckles. 15 turnbuckles of 5/8" x 9" are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
**Failure to use installation accessories such as brackets, tower base, tower anchor, or guy wire anchors will result in loss of equipment warranty, and any additional modifications are the responsibility of the installer.**
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe light with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted in 7 stripes of equal size; 4 orange-red stripes and 3 white stripes.
Lifeline system (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 3 | S-GULV | Line guide |
| 48 | SRET-338CAM | 3/8" cable |
| 6 | NUDO-38FJG | 3/8" forged clip |
| 2 | CUELLO-38-HDG | 3/8" thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety carriage for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
*NOM-009 mandates the use of systems that prevent accidental falls on a structure.
Grounding system recommended for tower and equipment mounted on it (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod Connector |
| 1 | TGBUSG10 | Bus Bar with 1000A Capacity Insulators (Cabinet not included) |
* It is recommended to use 4 AWG coated copper cable (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for Tower (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning Rod with Aluminum Mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp. Electrode with one bag of impedance-improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic inspection box. |
| 1 | ANTIOX | Aerosol for terminal protection. |
| 3 | TGCR11 | Eye Connector. |
| 2 | TGAB18 | Rod Connector. |
| 30 | TGAC114 | Tower insulator. |
*The dipole-type rod offers a 72° protection cone below the coil. Recommended for low lightning incidence zones.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering a maximum distance of 3 meters from the electrode to the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations:
- Ensure that the installation is performed by a trained professional.
- Schedule a maintenance plan for checking guy wire tension and tightening hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive twisting and bending in the tower, leading to structural failures.
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting).
- It is recommended to light the tower at least at the tip with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images