Wishlist

6 m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section. (Guy wires not included).

  • $ 12,199.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-30G-006

Key Features Product manufactured under ISO 9001:2015 standards High Elevation / Low cost 100% Section-by-Section Assembly Inspection Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008 Ideal for coastal areas with high humidity...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30G-006 , supplier:Syscom , syscom

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High Elevation / Low cost
  • 100% Section-by-Section Assembly Inspection
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
  • Ideal for coastal areas with high humidity or industrial zones

Physical Characteristics

  • Maximum Axial Load: 200 kg
  • Height: 6 meters (2 sections)
  • Wind resistance: 200 km/hr
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
  • Application: Outdoor (Humid Zones)
Includes the following components
  • Quantity: 2 - STZ30G - 30 cm face width tower section
  • Quantity: 1 - SCZ30PG - 30 cm tower top cap with set screw for lightning rod
  • Quantity: 1 - SBA30G - Base for 30 cm tower
  • Quantity: 1 - SAB30G - Anchor for tower base
  • Quantity: 1 - SJB30G - Guy wire clamp flange
  • Quantity: 3 - SAP02G - Ground anchor for guy wire
  • Quantity: 6 - CUELLO-14-HDG - Thimble for guy wire
  • Quantity: 18 - NUDO-316-FJG - 3/16' cable clamp
Complementary accessories (Not included)
  • Quantity: 2 - EIGSLSE - Autonomous LED strobe light with photocell, solar panel, and battery. Type L810
  • Quantity: 2 - HLU3R2 - Mounting for obstruction light EIGSLSE
Lifeline system (Not included)
  • Quantity: 1 - SHE-LV - Pair of mounting hardware
  • Quantity: 1 - S-GULV - Line guide
  • Quantity: 9 - SRET-338 - 3/8' cable
  • Quantity: 6 - NUDO-38FJG - 3/8' forged wire rope clip
  • Quantity: 2 - CUELLO-38-HDG - 3/8' thimble
  • Quantity: 1 - TRY-ACC-SLIDER - (Optional) Safety slider for installer
  • Quantity: 1 - SYS-USA7B - (Optional) Suspension harness
Recommended Grounding System for Tower and mounted equipment (Not included)
  • Quantity: 1 - TG45AB - 45 A grounding electrode with electrode, filter, and H2Ohm compound
  • Quantity: 1 - S610 - Plastic inspection well
  • Quantity: 3 - TGCR11 - Eye connector
  • Quantity: 2 - TGAB18 - Rod connector
  • Quantity: 1 - TGBUSG10 - 1000A capacity grounding busbar with insulators (Without cabinet)
Basic Lightning Rod System Recommended for Tower (Not included)
  • Quantity: 1 - TGTDPC - Lightning rod tip with aluminum mast (MASTIL1.2)
  • Quantity: 1 - TG45AB - 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level
  • Quantity: 1 - S610 - Small plastic inspection well
  • Quantity: 1 - ANTIOX - Spray for terminal protection
  • Quantity: 3 - TGCR11 - Eye connector
  • Quantity: 2 - TGAB18 - Rod connector
  • Quantity: 4 - TGAC - Tower insulator
Guy wire not included. 32 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.
Turnbuckles not included. 3 turnbuckles of 1/2' x 6' are recommended. (TEN1/2X6OGJ or TEN1/2X6OQJ).
*NOT using installation accessories such as flanges, tower base, tower anchor, or guy anchors is considered a forfeiture of the equipment warranty, and any additional adaptation is the responsibility of the installer.
* It is recommended to use 4 AWG insulated copper wire (SLY-287-GRN) to ground the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
*NOM-009 mandates the use of fall-arrest systems for work on a structure.
*The dipole-type tip offers a 72° protection cone under the coil. It is recommended for low lightning incidence zones.
*2/0 gauge copper wire is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
See connection diagram for Physical Ground + Lightning Rod: DIAGRAM

Recommendations

  • Ensure installation is performed by a trained professional
  • Schedule a maintenance plan to check guy wire tension and tighten hardware
  • Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts
  • A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting)
  • It is recommended to light the tower at least at the top with a red lamp
ROHN LOGO

New! Lightning Rod + Grounding Kit with Cable. LINKEDPRO Brand (Not included)

KLP-TZ06-PRO - All-inclusive! Ideal for 6m towers with corona dipole, wiring, and electrodes.

Or you can also quote the following grounding or lightning rod components individually:


Recently viewed