6 m Guyed Ground Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).

  • $ 18,399.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-35G-006

Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost. 100% inspection of section-by-section assembly. Hot-dip galvanized according to NMX-H-004-SCFI-2008 Ideal for high-humidity coastal areas or industrial...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35G-006 , supplier:Syscom , syscom

SYSCOM TOWERS Logo

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost.
  • 100% inspection of section-by-section assembly.
  • Hot-dip galvanized according to NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal areas or industrial zones.

Physical Characteristics

  • Maximum Axial Load: 350 kg.
  • Height: 6 meters (2 sections).
  • Wind resistance: 200 km/h.
  • Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
  • Application: Outdoor (Humid zones).

Includes the following components

Quantity Model Description
2 STZ35G Tower section with 35 cm face width.
1 SCZ35PG 35 cm tower top with lightning rod set screw.
1 SBZ35G 35 cm tower base.
1 SAB45G Anchor for 35/45 tower base.
1 SJB35G Guy wire tensioning bracket.
3 SAZ45G Floor anchor for guy wire.
6 CUELLO-14-HDG Thimble for guy wire
18 NUDO-316-FJG 3/16" wire rope clip.

Guy wire not included. 32 meters of 3/16" guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.

Turnbuckles not included. 3 turnbuckles of 5/8" x 9" are recommended (TEN5/8X9OGJ or TEN5/8X9OQJ).

Important: NOT using installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy Wire Anchors is considered a voiding of the equipment warranty, and any additional modifications are the sole responsibility of the installer.

Supplementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mounting for EIGSLSE obstruction light

* The signaling standard dictates that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.

Lifeline System (Not included)

Quantity Model Description
1 SHE-LV Pair of fastening brackets
1 S-GULV Line guide
9 SRET-338CAM 3/8" cable
6 NUDO-38FJG 3/8" forged wire rope clip
2 CUELLO-38-HDG 3/8" thimble
1 TRY-ACC-SLIDER (Optional) Safety carriage for installer.
1 SYS-USA7B (Optional) Suspension harness.

* NOM-009 mandates the use of systems to prevent accidental falls when working on a structure.

Grounding System Recommended for Tower and Equipment Mounted on it (Not included)

Quantity Model Description
1 TG45AB 45A grounding electrode with Electrode, Filter, and H2Ohm compound
1 S610 Plastic inspection box.
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 Busbar with insulators, 1000A capacity (without cabinet)

* The use of 4 AWG copper-clad cable (SLY-287-GRN) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Basic Lightning Protection System Recommended for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp. electrode with a bag of impedance-improving compound (H2OHM), compass, and level.
1 S610 Small plastic inspection box.
1 ANTIOX Aerosol for terminal protection.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
4 TGAC114 Tower insulator.

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.

See the connection diagram for Physical Ground + Lightning Rod in the following DIAGRAM.


Recommendations

  • Ensure the installation is performed by a trained professional.
  • Schedule a maintenance plan for checking guy wire tension and adjusting hardware.
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
  • A stress analysis must be performed when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
  • The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting).
  • It is recommended to illuminate the tower at least at the tip with a red lamp.

Representative Diagram: Guy Wire Installation Version 2.0