6 m Ground-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).
- $ 21,499.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: KTZ-45G-006
Key Features Product manufactured under ISO 9001:2015 standards High Elevation / Low cost 100% Assembly inspection section by section Hot-dip galvanized according to NMX-H-004-SCFI-2008 Ideal for high-humidity coastal zones or...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-45G-006 , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standards
- High Elevation / Low cost
- 100% Assembly inspection section by section
- Hot-dip galvanized according to NMX-H-004-SCFI-2008
- Ideal for high-humidity coastal zones or industrial areas
Physical Characteristics
- Maximum Axial Load: 500 kg
- Height: 6 meters (2 sections)
- Wind resistance: 200 km/hr
- Anticorrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 2 | STZ45G | 45 cm face width tower section |
| 1 | SCZ45G | 45 cm tower top cap with set screw for lightning rod |
| 1 | SBZ45G | 45 cm tower base |
| 1 | SAB45G | Anchor for 35/45 tower base |
| 1 | SJB45G | Guy wire attachment bracket |
| 3 | SAZ45G | Ground anchor for guy wire |
| 6 | CUELLO-14-HDG | Thimble for 1/4" guy wire |
| 18 | NUDO-14-FJG | 1/4" cable clamp |
Guy wire not included.
32 meters of 1/4" guy wire (SRET-635-CAM) or larger diameters are recommended.
Turnbuckles not included.
3 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
Failure to use installation accessories such as brackets, tower base, tower anchor, or guy anchors is considered a forfeiture of the equipment warranty, and any additional adaptation is the installer's responsibility.
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. L810 type |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction light |
* Signaling standards dictate that the tower must be painted in 7 bands of equal size; 4 bands in reddish-orange and 3 in white.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 9 | SRET-338CAM | 3/8" cable |
| 6 | NUDO-38FJG | 3/8" forged clamp |
| 2 | CUELLO-38-HDG | 3/8" thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Recommended Grounding System for Tower and Equipment Mounted on it (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Ground rod connector |
| 1 | TGBUSG10 | Bus bar with 1000A capacity insulators (No cabinet) |
* It is recommended to use 4 AWG insulated copper wire (SLY-287-GRN) to ground the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode with a bag of impedance improvement compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic access box |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye Connector |
| 2 | TGAB18 | Rod Connector |
| 4 | TGAC114 | Tower Insulator |
*The dipole-type tip offers a 72° protection cone under the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering a maximum electrode installation distance of 3 meters from the tower, approximately 8 meters are used.
DIAGRAM of Physical Ground + Lightning Rod connection
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting work)
- It is recommended to light the tower at least at the tip with a red lamp