Key Features
- Product manufactured under ISO 9001:2015 standards
- High elevation / Low cost
- 100% section-by-section assembly inspection
- Electrolytic galvanization in accordance with ASTM B-633 standards
- Ideal for dry, corrosion-free zones
Physical Characteristics
- Maximum Axial Load: 350 kg
- Height: 9 meters (3 sections)
- Wind resistance: 200 km/h
- Anti-corrosive protection: Electrolytic Galvanized (ASTM B-633)
- Application: Outdoors (Desert zones or low humidity)
Includes the following components
- 3 x STZ35 - 35 cm face width tower section
- 1 x SCZ35P - 35 cm tower top with lightning rod clamp
- 1 x SBZ35 - 35 cm tower base
- 1 x SAB45 - Anchor for 35/45 tower base
- 1 x SJB35 - Guy wire attachment flange
- 3 x SAZ45 - Ground anchor for guy wire
- 6 x CUELLO-14-HDG - Guy wire thimble
- 18 x NUDO-316-FJG - 3/16' cable clamp
Complementary accessories (Not included)
Guy wire not included. 42 meters of 3/16' guy wire is recommended (SRET-474-CAM or SRET-316-DA) or larger diameters.
Turnbuckles not included. 3 turnbuckles of 5/8' x 9' are recommended (TEN5/8X9OGJ or TEN5/8X9OQJ).
*Failure to use installation accessories such as flanges, tower base, tower anchor, or guy anchors is considered a voiding of the equipment warranty, and any additional modifications are the sole responsibility of the installer.
Signaling/Lighting System (Not included)
- 2 x EIGSLSE - Autonomous LED strobe with photocell, solar panel, and battery. Type L810
- 2 x HLU3R2 - Mount for EIGSLSE obstruction lamp
*Signaling standards dictate that the tower must be painted in 7 alternating bands of equal size; 4 orange-red bands and 3 white bands.
Lifeline system (Not included)
*NOM-009 mandates the use of fall protection systems on structures.
Recommended Grounding System for Tower and Mounted Equipment (Not included)
- 1 x TG45AB - 45 A grounding electrode with filter and H2Ohm compound
- 1 x S610 - Plastic inspection well
- 3 x TGCR11 - Eye connector
- 2 x TGAB18 - Rod connector
- 1 x TGBUSG10 - 1000A capacity busbar with insulators (No cabinet)
*Use of 4 AWG coated copper wire (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included)
- 1 x TGTDPC - Lightning rod with aluminum mast (MASTIL1.2)
- 1 x TG45AB - 45 Amp electrode with H2OHM impedance improvement compound, compass, and level
- 1 x S610 - Small plastic inspection well
- 1 x ANTIOX - Anti-corrosion terminal spray
- 3 x TGCR11 - Eye connector
- 2 x TGAB18 - Rod connector
- 6 x TGAC114 - Tower insulator
*The dipole tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper wire is recommended for integration (SLY-346-BLK). Assuming electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
View the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending, resulting in structural failure
- The tower must be painted in orange-red and white, in 7 bands of equal height starting and ending with orange-red (SYSCOM does not perform tower painting)
- It is recommended to illuminate the tower, at least at the top, with a red lamp
Representative Diagram
Guy Installation Version 2.0