9 m Ground-Based Guyed Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).

  • $ 22,399.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-35G-009

Key Features: Product manufactured under ISO 9001:2015 standards High Elevation / Low cost. 100% Section-by-section assembly inspection. Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008 Ideal for high-humidity coastal zones or industrial...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35G-009 , supplier:Syscom , syscom

Logo SYSCOM TOWERS

Key Features:

  • Product manufactured under ISO 9001:2015 standards
  • High Elevation / Low cost.
  • 100% Section-by-section assembly inspection.
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal zones or industrial areas.

Physical Features:

  • Maximum Axial Load: 350 kg.
  • Height: 9 meters (3 sections).
  • Wind resistance: 200 km/h.
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
  • Application: Outdoor (Humid Zones).

Includes the following components:

Quantity Model Description
3 STZ35G Tower section with 35 cm face width.
1 SCZ35PG 35 cm tower top cap with lightning rod clamp.
1 SBZ35G 35 cm tower base.
1 SAB45G Tower base anchor 35/45.
1 SJB35G Guy wire support flange.
3 SAZ45G Floor anchor for guy wire.
6 CUELLO-14-HDG Thimble for guy wire
18 NUDO-316-FJG 3/16' cable clamp.

Guy wire not included. 42 meters of 3/16' guy wire is recommended ( SRET-474-CAM or SRET-316-DA) or larger diameters.

Turnbuckles not included. 3 turnbuckles of 5/8' x 9' are recommended ( TEN5/8X9OGJ or TEN5/8X9OQJ).

**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will be considered a voiding of the equipment warranty, and any additional adaptation is the responsibility of the installer.**

Supplementary Accessories (Not included):

Signaling/Lighting System (Not included):

Quantity Model Description
2 EIGSLSE Autonomous LED strobe type with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mount for EIGSLSE obstruction light

*Signaling standards dictate that the tower must be painted in 7 bands of equal size; 4 bands in reddish-orange tone and 3 in white.

Lifeline System (Not included):

Quantity Model Description
1 SHE-LV Pair of fastening hardware
1 S-GULV Line guide
12 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged clamp
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer.
1 SYS-USA7B (Optional) Suspension harness.

*NOM-009 mandates the use of systems that arrest accidental falls on a structure.

Recommended Grounding System for Tower and Mounted Equipment (Not included):

Quantity Model Description
1 TG45AB 45A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic access box.
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 Grounding bus bar with 1000A capacity insulators (No cabinet)

* The use of 4 AWG jacketed copper cable ( SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG ( SLY-291-GRN) can be used.

Recommended Basic Lightning Rod System for Tower (Not included):

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp electrode. With one bag of impedance-improving compound (H2OHM), compass, and level.
1 S610 Small plastic inspection box.
1 ANTIOX Terminal protection spray.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
6 TGAC114 Tower insulator.

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.

See the physical ground + lightning rod connection diagram in the following DIAGRAM.

Recommendations:

  • Ensure that the installation is performed by a trained professional.
  • Schedule a maintenance plan for checking guy wire tension and adjusting hardware.
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
  • A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure.
  • The tower must be painted in an orange-red and white tone, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting).
  • It is recommended to light the tower, at least at the tip, with a red lamp.

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram

Installation Images

Installation Images