9 m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).

9 m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).

Regular price $ 26,699.00
Regular price Sale price $ 26,699.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple Paga con tarjeta, Apple Pay o PayPal ¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096

SYSCOM TOWERS

Key Features

  • Product manufactured under ISO 9001:2015 standard
  • High elevation / Low cost.
  • 100% Section-by-section assembly inspection.
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal areas or industrial zones.

Physical Characteristics

  • Maximum Axial Load: 500 kg.
  • Height: 9 meters (3 sections).
  • Wind resistance: 200 km/h.
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
  • Application: Outdoor (Humid zones).

Includes the following components

Quantity Model Description
3 STZ45G Tower section with 45 cm face width.
1 SCZ45G 45 cm tower top with lightning rod set screw.
1 SBZ45G Base for 45 cm tower.
1 SAB45G Anchor for 35/45 tower base.
1 SJB45G Guy wire support flange.
3 SAZ45G Floor anchor for guy wire.
6 CUELLO-14-HDG Thimble for guy wire
18 NUDO-14-FJG 1/4" wire rope clip.

Guy wire not included. 42 meters of 1/4" guy wire (SRET-635-CAM) or larger diameters are recommended.

Turnbuckles not included. 3 turnbuckles of 5/8" x 9" are recommended (TEN5/8X9OGJ or TEN5/8X9OQJ).

Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will result in the loss of the equipment warranty, and any additional modification is the responsibility of the installer.

Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. L810 type.
2 HLU3R2 Mounting for EIGSLSE obstruction lamp

* Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white bands.

Lifeline system (Not included)

Quantity Model Description
1 SHE-LV Pair of fastening brackets
1 S-GULV Line guide
12 SRET-338CAM 3/8" cable
6 NUDO-38FJG 3/8" forged clip
2 CUELLO-38-HDG 3/8" thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer.
1 SYS-USA7B (Optional) Suspension harness.

*NOM-009 mandates the use of systems that arrest accidental falls on a structure.

Recommended Grounding System for Tower and mounted equipment (Not included)

Quantity Model Description
1 TG45AB 45A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic access box.
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 1000A capacity grounding bus bar with insulators (without enclosure)

* The use of 4 AWG jacketed copper cable (SLY-287-GRN) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG cable (SLY-291-GRN) can be used.

Basic Lightning Protection System Recommended for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level.
1 S610 Small plastic access box.
1 ANTIOX Terminal protection spray.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
6 TGAC114 Tower insulator.

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.

See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM.

Recommendations

  • Ensure that the installation is performed by a trained professional.
  • Schedule a maintenance plan to check guy wire tension and tighten hardware.
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
  • A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
  • The tower must be painted in orange-red and white tones, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting work).
  • It is recommended to illuminate the tower at least at the tip with a red lamp.