Wishlist

12m Roof Guyed Tower Kit with STZ30 Electro-Galvanized Section (Guy wire not included).

  • $ 14,599.00
  • Brand: SYSCOM TOWERS
  • Availability: 2 In stock
  • SKU: KTZ-30E-012P

Key Features Product manufactured under ISO 9001:2015 standards. High elevation / Low cost. 100% inspection of section-by-section assembly. Electrolytic galvanization in accordance with ASTM B-633 standards. Ideal for dry areas...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30E-012P , supplier:Syscom , syscom

SYSCOM TOWERS Logo

Key Features

  • Product manufactured under ISO 9001:2015 standards.
  • High elevation / Low cost.
  • 100% inspection of section-by-section assembly.
  • Electrolytic galvanization in accordance with ASTM B-633 standards.
  • Ideal for dry areas free of corrosion.

Physical Characteristics

  • Maximum Axial Load: 200 kg.
  • Height: 12 meters (4 sections).
  • Wind Resistance: 200 km/h.
  • Anti-corrosion protection: Electrolytic Galvanization (ASTM B-633).
  • Application: Outdoor (Desert or low-humidity zones).

Includes the following components

Quantity Model Description
4 STZ30 30 cm face width tower section.
1 SCZ30P 30 cm tower cap with set screw for lightning rod.
1 SBA30 30 cm tower base.
1 SAB30 Tower base anchor.
2 SJB30 Guy wire support flange.
3 SAP01 Wall anchor for guy wire.
12 CUELLO-14-HDG Thimble for guy wire.
36 NUDO-316-FJG 3/16' wire rope clip.

Does not include guy wire. 100 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.

Does not include turnbuckles. 6 turnbuckles of 1/2' x 6' are recommended. (TEN1/2X6OGJ or TEN1/2X6OQJ).

Warning:

Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will result in the loss of the equipment warranty, and any additional modifications are the responsibility of the installer.

Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Self-contained LED strobe with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mount for EIGSLSE obstruction light.

* The signaling standard dictates that the tower must be painted in 7 bands of equal size; 4 bands in reddish-orange and 3 in white.

Lifeline system (Not included)

Quantity Model Description
1 SHE-LV Pair of mounting brackets.
1 S-GULV Line guide.
15 SRET-338 3/8' cable.
6 NUDO-38FJG 3/8' forged cable clip.
2 CUELLO-38-HDG 3/8' thimble.
1 TRY-ACC-SLIDER (Optional) Safety carriage for installer.
1 SYS-USA7B (Optional) Suspension harness.

* NOM-009 makes it mandatory to use systems that stop accidental falls on a structure.

New! Lightning rod + Grounding kit with cable (Not included)

KLP-TZ12-PRO - All-inclusive! Ideal for 12m towers with corona dipole, wiring, and electrodes.

Or you can quote the following Grounding or Lightning rod components individually:

Grounding System Recommended for Tower and Mounted Equipment (Not included)

Quantity Model Description
1 TG45AB 45A grounding electrode with electrode, filter, and H2Ohm compound.
1 S610 Plastic access box.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
1 TGBUSG10 Grounding bus bar with 1000A capacity insulators (no cabinet).

* It is recommended to use insulated copper cable 4 AWG (SLY-287-GRN) to ground the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Basic Lightning Rod System Recommended for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2).
1 TG45AB 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level.
1 S610 Small plastic inspection box.
1 ANTIOX Aerosol for terminal protection.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
8 TGAC Tower insulator.

*The dipole-type tip offers a 72° cone of protection below the coil. It is recommended for areas with low lightning incidence.

*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.

See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM.

Recommendations

  • Ensure the installation is performed by a trained professional.
  • Schedule a maintenance plan to check guy wire tension and tighten hardware.
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
  • A stress study must be performed when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
  • The tower must be painted in reddish-orange and white, in 7 stripes of equal height, starting and ending with reddish-orange (SYSCOM does not perform tower painting).
  • It is recommended to illuminate the tower, at least at the tip, with a red lamp.

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram Version 2.0

Installation Images

Installation Images

Recently viewed