SYSCOM TOWERS
12 m Roof-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).
12 m Roof-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standard
- High elevation / Low cost
- 100% section-by-section assembly inspection
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
- Ideal for coastal areas with high humidity or industrial zones
Physical Characteristics
- Maximum Axial Load: 200 kg
- Height: 12 meters (4 sections)
- Wind resistance: 200 km/h
- Corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoors (Humid zones)
Includes the following components
Guy wire not included. 100 meters of 1/8' guy wire SRET-318-CAM or larger diameters are recommended.
Turnbuckles not included. 6 turnbuckles of 1/2' x 6' are recommended. TEN1/2X6OGJ or TEN1/2X6OQJ.
- Quantity: 4 | Model: STZ30G | Description: 30 cm face width tower section
- Quantity: 1 | Model: SCZ30PG | Description: 30 cm tower top with lightning rod set screw
- Quantity: 1 | Model: SBA30G | Description: 30 cm tower base
- Quantity: 1 | Model: SAB30G | Description: Tower base anchor
- Quantity: 2 | Model: SJB30G | Description: Guy wire bracket
- Quantity: 3 | Model: SAP01G | Description: Slab or wall anchor for guy wire
- Quantity: 12 | Model: CUELLO-14-HDG | Description: Thimble for guy wire
- Quantity: 36 | Model: NUDO-316-FJG | Description: 3/16' cable clamp
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
* Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 in orange-red and 3 in white.
Lifeline system (Not included)
- Quantity: 1 | Model: SHE-LV | Description: Pair of fastening brackets
- Quantity: 1 | Model: S-GULV | Description: Cable guide
- Quantity: 15 | Model: SRET-338CAM | Description: 3/8' cable
- Quantity: 6 | Model: NUDO-38FJG | Description: 3/8' forged clamp
- Quantity: 2 | Model: CUELLO-38-HDG | Description: 3/8' thimble
- Quantity: 1 | Model: TRY-ACC-SLIDER | Description: (Optional) Safety slider for installer
- Quantity: 1 | Model: SYS-USA7B | Description: (Optional) Suspension harness
*NOM-009 mandates the use of systems to arrest accidental falls on a structure.
New! Lightning Rod + Grounding Kit with Cable. LINKEDPRO Brand (Not included)
KLP-TZ12-PRO - All-inclusive! Ideal for 12m towers with corona dipole, wiring, and electrodes.
Or you can individually quote the following Grounding or Lightning Rod components:
Recommended Grounding System for Tower and Equipment (Not included)
- Quantity: 1 | Model: TG45AB | Description: 45A grounding electrode with electrode, filter, and H2Ohm compound
- Quantity: 1 | Model: S610 | Description: Plastic inspection box
- Quantity: 3 | Model: TGCR11 | Description: Eye connector
- Quantity: 2 | Model: TGAB18 | Description: Rod connector
- Quantity: 1 | Model: TGBUSG10 | Description: 1000A capacity ground bus bar with insulators (without cabinet)
* 4 AWG insulated copper cable SLY-287-GRN is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG SLY-291-GRN can be used.
Basic Recommended Lightning Rod System for Tower (Not included)
- Quantity: 1 | Model: TGTDPC | Description: Lightning rod tip with aluminum mast (MASTIL1.2)
- Quantity: 1 | Model: TG45AB | Description: 45 Amp electrode. Includes a bag of impedance-improving compound (H2OHM), compass, and level
- Quantity: 1 | Model: S610 | Description: Small plastic inspection box
- Quantity: 1 | Model: ANTIOX | Description: Terminal protection spray
- Quantity: 3 | Model: TGCR11 | Description: Eye connector
- Quantity: 2 | Model: TGAB18 | Description: Rod connector
- Quantity: 8 | Model: TGAC | Description: Tower insulator
*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable SLY-346-BLK is recommended for the integration. Considering a maximum installation distance of 3 meters from the tower, approximately 8 meters are used.
See the Earth Ground + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 bands of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting work)
- It is recommended to illuminate the tower at least at the tip with a red light
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images