Skip to product information
1 of 1

SYSCOM TOWERS

15m Roof-Mounted Guyed Tower Kit with Electro-Galvanized STZ30 Section (Guy wire not included).

15m Roof-Mounted Guyed Tower Kit with Electro-Galvanized STZ30 Section (Guy wire not included).

Regular price $ 17,899.00
Regular price Sale price $ 17,899.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple Paga con tarjeta, Apple Pay o PayPal ¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096

Key Features

  • Product manufactured under ISO 9001:2015 standards.
  • High elevation / Low cost.
  • 100% section-by-section assembly inspection.
  • Electrolytic galvanization according to ASTM B-633 standard.
  • Ideal for dry, corrosion-free zones.

Physical Characteristics

  • Maximum Axial Load: 200 kg.
  • Height: 15 meters (5 sections).
  • Wind resistance: 200 km/h.
  • Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633).
  • Application: Outdoor (desert or low-humidity areas).

Includes the following components

Quantity Model Description
5 STZ30 Tower section with 30 cm face width.
1 SCZ30P 30 cm tower top with lightning rod set screw.
1 SBA30 30 cm tower base.
1 SAB30 Tower base anchor.
3 SJB30 Guy wire attachment flange.
3 SAP01 Slab or wall anchor for guy wire.
18 CUELLO-14-HDG Thimble for guy wire.
54 NUDO-316-FJG 3/16' cable clamp.

Guy wire not included. 160 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.

Turnbuckles not included. 9 turnbuckles of 1/2' x 6' are recommended (TEN1/2X6OGJ or TEN1/2X6OQJ).

**NOT using installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will be considered a voidance of the equipment warranty, and any additional adaptation remains the responsibility of the installer.**


Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. Type L810.
2 HLU3R2 Mount for EIGSLSE obstruction lamp.

*Signaling standards dictate that the tower must be painted in 7 bands of equal size; 4 reddish-orange bands and 3 white bands.

Lifeline system (Not included)

Quantity Model Description
1 SHE-LV Pair of fastening brackets.
1 S-GULV Line guide.
18 SRET-338CAM 3/8' cable.
6 NUDO-38FJG 3/8' forged clamp.
2 CUELLO-38-HDG 3/8' thimble.
1 TRY-ACC-SLIDER (Optional) Safety slider for installer.
1 SYS-USA7B (Optional) Suspension harness.

*NOM-009 mandates the use of systems that break accidental falls on a structure.


New! Lightning rod + Grounding kit with cable (Not included)

KLP-TZ15-PRO - All-inclusive! Ideal for 15 m towers with crown dipole, wiring, and electrodes.

Alternatively, you can quote the following Grounding or Lightning rod components individually:

Grounding System Recommended for Tower and equipment mounted on it (Not included)

Quantity Model Description
1 TG45AB 45 A grounding electrode with Electrode, Filter, and H2Ohm compound.
1 S610 Plastic junction box.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
1 TGBUSG10 Grounding bus bar with insulators, 1000A capacity (without cabinet).

* 4 AWG coated copper cable (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG cable (SLY-291-GRN) can be used.

Basic Lightning Rod System Recommended for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2).
1 TG45AB 45 Amp electrode. With a bag of impedance-improving compound (H2OHM), compass, and level.
1 S610 Small plastic junction box.
1 ANTIOX Terminal protection spray.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
10 TGAC Tower insulator.

The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.

2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering the electrode is installed at a maximum of 3 meters from the tower, approximately 8 meters are used.

See Grounding + Lightning Rod connection diagram: DIAGRAM


Recommendations

  • Ensure that the installation is performed by a trained professional.
  • Schedule a maintenance plan to check guy wire tension and tighten hardware.
  • Do not install solar panels at a height greater than 6 meters. Check the compatibility between solar cells and mounts.
  • A stress analysis must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failures.
  • The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting).
  • It is recommended to illuminate the tower at least at the top with a red lamp.

Representative Diagram: Guy Installation Version 2.0

Installation Images

View full details