15 m Roof Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).
- $ 22,599.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: KTZ-30G-015P
Key Features Product manufactured under ISO 9001:2015 standard High elevation / Low cost 100% Inspection of section-by-section assembly Hot-dip galvanized according to NMX-H-004-SCFI-2008 Ideal for coastal areas with high humidity...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30G-015P , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standard
- High elevation / Low cost
- 100% Inspection of section-by-section assembly
- Hot-dip galvanized according to NMX-H-004-SCFI-2008
- Ideal for coastal areas with high humidity or industrial zones
Physical Characteristics
- Maximum Axial Load: 200 kg
- Height: 15 meters (5 sections)
- Wind resistance: 200 km/hr
- Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 5 | STZ30G | Tower section 30 cm face width |
| 1 | SCZ30PG | 30 cm tower top with lightning rod set screw |
| 1 | SBA30G | Base for 30 cm tower |
| 1 | SAB30G | Anchor for tower base |
| 3 | SJB30G | Guy wire bracket |
| 3 | SAP01G | Slab or wall anchor for guy wire |
| 18 | CUELLO-14-HDG | Thimble for guy wire |
| 54 | NUDO-316-FJG | 3/16' cable clamp (wire rope clip) |
Guy wire not included. 160 meters of 1/8' SRET-318-CAM guy wire or larger diameters are recommended.
Turnbuckles not included. 9 turnbuckles of 1/2' x 6' are recommended. TEN1/2X6OGJ or TEN1/2X6OQJ
**Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor or Guy Wire Anchors is considered a voidance of the equipment warranty, and any additional adaptation is the responsibility of the installer.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe light with photocell, solar panel and battery. Type L810 |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction light |
* The signaling standard dictates that the tower must be painted in 7 equal-sized bands; 4 in orange-red tone and 3 in white
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Cable guide |
| 18 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged cable clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety carriage for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
* NOM-009 mandates the use of systems that arrest accidental falls on a structure
Recommended Grounding System for Tower and Equipment mounted on it
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A Grounding electrode with Electrode, Filter and H2Ohm compound |
| 1 | S610 | Plastic inspection well |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Connector for rod |
| 1 | TGBUSG10 | Bonding bar with insulators 1000A capacity (without enclosure) |
* It is recommended to use 4 AWG cal. coated copper wire SLY-287-GRN for grounding the electrode to the tower. For equipment on the tower, you can use 6 AWG cal. SLY-291-GRN
Recommended Basic Lightning Protection System for Tower
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with Aluminum Mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass and level |
| 1 | S610 | Small plastic inspection well |
| 1 | ANTIOX | Protective spray for terminals |
| 3 | TGCR11 | Eye terminal connector |
| 2 | TGAB18 | Rod connector |
| 10 | TGAC | Tower insulator |
*The dipole-type tip provides a 72° protection cone under the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper wire is recommended for the integration SLY-346-BLK. Considering the electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels higher than 6 meters. Check for compatibility between solar cells and mounts
- A stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting)
- It is recommended to illuminate the tower at least at the tip with a red light