18m Roof-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).

  • $ 25,099.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-30G-018P

Key Features Standard: ISO 9001:2015 High Elevation / Low cost 100% Section-by-Section Assembly Inspection Galvanization: Hot-dip (NMX-H-004-SCFI-2008) Ideal for high-humidity coastal zones or industrial areas Physical Characteristics Maximum Axial Load:...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30G-018P , supplier:Syscom , syscom

SYSCOM TOWERS Logo

Key Features

  • Standard: ISO 9001:2015
  • High Elevation / Low cost
  • 100% Section-by-Section Assembly Inspection
  • Galvanization: Hot-dip (NMX-H-004-SCFI-2008)
  • Ideal for high-humidity coastal zones or industrial areas

Physical Characteristics

  • Maximum Axial Load: 200 Kg
  • Height: 18 meters (6 sections)
  • Wind Resistance: 200 km/hr
  • Anti-corrosion protection: Hot-dip galvanization (NMX-H-004-SCFI-2008)
  • Application: Outdoor (Humid zones)
Includes the following components
  • Quantity: 6 - STZ30G - 30 cm face width tower section
  • Quantity: 1 - SCZ30PG - 30 cm tower top with set screw for lightning rod
  • Quantity: 1 - SBA30G - Base for 30 cm tower
  • Quantity: 1 - SAB30G - Anchor for tower base
  • Quantity: 3 - SJB30G - Guy wire clamp flange
  • Quantity: 3 - SAP01G - Slab or wall anchor for guy wire
  • Quantity: 18 - CUELLO-14-HDG - Thimble for guy wire
  • Quantity: 54 - NUDO-316-FJG - 3/16' cable clamp

Guy wire not included. 190 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.

Turnbuckles not included. 9 1/2' x 6' turnbuckles are recommended. (TEN1/2X6OGJ or TEN1/2X6OQJ).

**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional adaptation is the responsibility of the installer.**

Complementary accessories (Not included)
  • Signaling/Lighting System (Not included)
Lifeline system (Not included)

*NOM-009 mandates the use of systems that prevent accidental falls on a structure.

Recommended Grounding System
  • Quantity: 1 - TG45AB - 45 A grounding electrode with electrode, filter, and H2Ohm compound
  • Quantity: 1 - S610 - Plastic inspection box
  • Quantity: 3 - TGCR11 - Eye connector
  • Quantity: 2 - TGAB18 - Rod connector
  • Quantity: 1 - TGBUSG10 - Bonding bar with 1000A capacity insulators (No cabinet)

* 4 AWG coated copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Recommended Basic Lightning Rod System
  • Quantity: 1 - TGTDPC - Corona dipole lightning rod tip
  • Quantity: 1 - TG45AB - 45 Amp electrode. With one bag of enhancing compound (H2OHM), compass, and level
  • Quantity: 1 - S610 - Small plastic inspection box
  • Quantity: 1 - ANTIOX - Terminal protection aerosol
  • Quantity: 3 - TGCR11 - Eye connector
  • Quantity: 2 - TGAB18 - Rod connector
  • Quantity: 12 - TGAC - Down conductor cable insulator

*The dipole tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.

*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.

See Grounding + Lightning Rod connection diagram: DIAGRAM

Recommendations

  • Ensure the installation is performed by a trained professional
  • Schedule a maintenance plan for checking guy tension and adjusting hardware
  • Do not install solar panels at heights over 6 meters. Check compatibility between solar cells and mounts
  • A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not provide tower painting services)
  • It is recommended to illuminate the tower at least at the tip with a red lamp

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram Version 2.0

Installation Images

Guyed Tower Installation Image