21 m Roof-Mounted Guyed Tower Kit with Galvanized STZ30 Section (Guy wire not included).
- $ 23,499.00
- Brand: SYSCOM TOWERS
- Availability: Out of stock
- SKU: KTZ-30E-021P
Highlighted Features: Product manufactured under ISO 9001:2015 standards. High elevation / Low cost. 100% inspection of assembly section by section. Electrolytic galvanized in accordance with ASTM B-633 standards. Ideal for...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30E-021P , supplier:Syscom , syscom
Highlighted Features:
- Product manufactured under ISO 9001:2015 standards.
- High elevation / Low cost.
- 100% inspection of assembly section by section.
- Electrolytic galvanized in accordance with ASTM B-633 standards.
- Ideal for dry, corrosion-free areas.
Physical Characteristics:
- Maximum Axial Load: 200 kg.
- Height: 21 meters (7 sections).
- Wind resistance: 200 km/h.
- Corrosion protection: Electrolytic Galvanized (ASTM B-633).
- Application: Outdoor (Desert or low-humidity areas).
Includes the following components:
| Quantity | Model | Description |
|---|---|---|
| 7 | STZ30 | Tower section with 30 cm face width. |
| 1 | SCZ30P | 30 cm tower top with set screw for lightning rod. |
| 1 | SBA30 | Base for 30 cm tower. |
| 1 | SAB30 | Anchor for tower base. |
| 4 | SJB30 | Guy wire tension clamp. |
| 3 | SAP01 | Slab or wall anchor for guy wire. |
| 24 | CUELLO-14-HDG | Thimble for guy wire |
| 72 | NUDO-316-FJG | 3/16' wire rope clip. |
Does not include guy wire. We recommend 290 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters.
Does not include turnbuckles. We recommend 12 1/2' x 6' turnbuckles (TEN1/2X6OGJ or TEN1/2X6OQJ).
**Failure to use installation accessories such as clamps, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the responsibility of the installer.**
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 in reddish-orange and 3 in white.
Lifeline system (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of fastening brackets |
| 1 | S-GULV | Line guide |
| 24 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
*NOM-009 mandates the use of systems that stop accidental falls on a structure.
New! Lightning Rod Kit + Grounding with Cable. Brand: LINKEDPRO (Not included):
KLP-TZ21-PRO.- All-inclusive! Ideal for 21 m towers with corona dipole, wiring, and electrodes.
Or you may also quote the following grounding or lightning rod components individually:
Grounding System Recommended for the Tower and Equipment mounted on it (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity ground bus bar with insulators (without cabinet) |
* The use of 4 AWG coated copper wire (SLY-287-GRN) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG wire (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for the Tower (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning Rod Tip with Aluminum Mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp Electrode with a bag of impedance-improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic inspection well. |
| 1 | ANTIOX | Aerosol for terminal protection. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 14 | TGAC | Tower insulator. |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper wire is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
See the Physical Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations:
- Ensure the installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white tones, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting work).
- It is recommended to illuminate the tower, at least at the top, with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images