21 m Roof Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).

21 m Roof Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).

Regular price $ 29,099.00
Regular price Sale price $ 29,099.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple Paga con tarjeta, Apple Pay o PayPal ¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096

SYSCOM TOWERS Logo

Key Features

  • Product manufactured under ISO 9001:2015 standards.
  • High elevation / Low cost.
  • 100% section-by-section assembly inspection.
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
  • Ideal for high-humidity coastal areas or industrial sites.

Physical Characteristics

  • Maximum Axial Load: 200 kg.
  • Height: 21 meters (7 sections).
  • Wind Resistance: 200 km/h.
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
  • Application: Outdoor (Humid zones).

Includes the following components

Tower Components
  • 7 units - STZ30G: 30 cm face width tower section.
  • 1 unit - SCZ30PG: 30 cm tower top with lightning rod set screw.
  • 1 unit - SBA30G: 30 cm tower base.
  • 1 unit - SAB30G: Tower base anchor.
  • 4 units - SJB30G: Guy wire attachment flange.
  • 3 units - SAP01G: Slab or wall anchor for guy wire.
  • 24 units - CUELLO-14-HDG: Guy wire thimble.
  • 72 units - NUDO-316-FJG: 3/16' cable clamp.

Guy wire not included. 290 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.

Turnbuckles not included. 12 1/2' x 6' turnbuckles are recommended (TEN1/2X6OGJ or TEN1/2X6OQJ).

**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will be considered a voiding of the equipment warranty, and any additional adaptation is the responsibility of the installer.**

Complementary Accessories (Not included)

Signaling/Lighting System (Not included)

Components
  • 2 units - EIGSLSE: Autonomous LED strobe light with photocell, solar panel, and battery. Type L810.
  • 2 units - HLU3R2: Mounting for EIGSLSE obstruction light.

*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.

Lifeline system (Not included)

Components
  • 1 unit - SHE-LV: Pair of mounting brackets.
  • 1 unit - S-GULV: Line guide.
  • 24 units - SRET-338CAM: 3/8' cable.
  • NUDO-38FJG: 3/8' forged cable clamp.
  • 2 units - CUELLO-38-HDG: 3/8' thimble.
  • 1 unit - TRY-ACC-SLIDER: (Optional) Safety carriage for installer.
  • 1 unit - SYS-USA7B: (Optional) Suspension harness.

*NOM-009 mandates the use of systems that stop accidental falls on a structure.

New! Lightning Rod Kit + Grounding with Cable (Not included)

KLP-TZ21-PRO - All-inclusive! Ideal for 21m towers with corona dipole, wiring, and electrodes.

You can also quote the following Grounding or Lightning Rod components individually:

Recommended Grounding System for Tower and Mounted Equipment (Not included)

Components
  • 1 unit - TG45AB: 45A grounding electrode with electrode, filter, and H2Ohm compound.
  • 1 unit - S610: Plastic access box.
  • TGCR11: Eye connector.
  • 2 units - TGAB18: Rod connector.
  • 1 unit - TGBUSG10: Connection bar with 1000A capacity insulators (No cabinet).

* 4 AWG coated copper cable (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Recommended Basic Lightning Protection System for Tower (Not included)

Components
  • 1 unit - TGTDPC: Corona dipole lightning rod tip.
  • 1 unit - TG45AB: 45 Amp electrode. With one bag of improving compound (H2OHM), compass, and level.
  • 1 unit - S610: Small plastic access box.
  • 1 unit - ANTIOX: Terminal protection spray.
  • TGCR11: Eye connector.
  • 2 units - TGAB18: Rod connector.
  • 14 units - TGAC: Down conductor insulator.

*The dipole tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.

*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering the electrode is installed at a maximum of 3 meters from the tower, approx. 8 meters are used.

See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.

Recommendations

  • Ensure installation is carried out by a trained professional.
  • Schedule a maintenance plan for checking guy wire tension and adjusting hardware.
  • Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts.
  • A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending, leading to structural failure.
  • The tower must be painted in reddish-orange and white, in 7 bands of equal height, starting and ending with reddish-orange (SYSCOM does not perform tower painting).
  • It is recommended to light the tower at least at the top with a red lamp.