24m Roof Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).
- $ 31,599.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: KTZ-30G-024P
Key Features Product manufactured under ISO 9001:2015 standard Great elevation / Low cost 100% inspection of assembly section by section Hot-dip galvanized according to NMX-H-004-SCFI-2008 Ideal for coastal areas with...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30G-024P , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standard
- Great elevation / Low cost
- 100% inspection of assembly section by section
- Hot-dip galvanized according to NMX-H-004-SCFI-2008
- Ideal for coastal areas with high humidity or industrial areas
Physical Features
- Maximum Axial Load: 200 kg
- Height: 24 meters (8 sections)
- Wind resistance: 200 km/h
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid areas)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 8 | STZ30G | 30 cm face width tower section |
| 1 | SCZ30PG | 30 cm tower top with lightning rod clamp |
| 1 | SBA30G | 30 cm tower base |
| 1 | SAB30G | Tower base anchor |
| 4 | SJB30G | Guy wire clamp |
| 3 | SAP01G | Slab or wall anchor for guy wire |
| 24 | CUELLO-14-HDG | Thimble for guy wire |
| 72 | NUDO-316-FJG | 3/16' cable clamp (bulldog clip) |
Guy wire not included. 315 meters of 1/8' guy wire SRET-318-CAM or larger diameters are recommended.
Turnbuckles not included. 12 1/2' x 6' turnbuckles are recommended. TEN1/2X6OGJ or TEN1/2X6OQJ.
Failure to use installation accessories such as clamps, tower base, tower anchor, or guy wire anchors will void the equipment warranty, and any additional adaptations are the responsibility of the installer.
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of fastening brackets |
| 1 | S-GULV | Line guide |
| 27 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged cable clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
New! Lightning rod kit + Grounding system with cable. Brand: LINKEDPRO (Not included)
KLP-TZ24-PRO - Everything included! Ideal for 24m towers with corona dipole, cabling, and electrodes.
You can also quote the following grounding or lightning rod components individually:
Recommended grounding system for tower and mounted equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity ground bus bar with insulators (no enclosure) |
* The use of 4 AWG coated copper cable SLY-287-GRN is recommended for electrode-to-tower grounding. For equipment on the tower, 6 AWG SLY-291-GRN can be used.
Basic lightning rod system recommended for tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Corona dipole lightning rod tip |
| 1 | TG45AB | 45 Amp electrode with a bag of enhancing compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic access box |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 16 | TGAC | Down-conductor insulator |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for low lightning incidence zones.
*2/0 gauge copper cable is recommended for the integration SLY-346-BLK. Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels at a height greater than 6 meters. Check the compatibility between solar cells and mounts
- A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting work)
- It is recommended to illuminate the tower at least at the top with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images