SYSCOM TOWERS
30m Roof-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wires not included).
30m Roof-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wires not included).
Couldn't load pickup availability

Key Features:
- Product manufactured under ISO 9001:2015 standards.
- Great height / Low cost.
- 100% Section-by-section assembly inspection.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for high-humidity coastal zones or industrial areas.
Physical Specifications:
- Maximum Axial Load: 200 kg.
- Height: 30 meters (10 sections).
- Wind Resistance: 200 km/h.
- Anti-corrosion Protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components:
| Quantity | Model | Description |
|---|---|---|
| 10 | STZ30G | Tower section with 30 cm face width. |
| 1 | SCZ30PG | 30 cm tower top cap with lightning rod clamp. |
| 1 | SBA30G | Base for 30 cm tower. |
| 1 | SAB30G | Tower base anchor. |
| 5 | SJB30G | Guy wire support flange. |
| 3 | SAP01G | Slab or wall anchor for guy wire. |
| 30 | CUELLO-14-HDG | Thimble for guy wire |
| 90 | NUDO-316-FJG | 3/16' wire rope clip. |
Does not include guy wire. 480 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.
Does not include turnbuckles. 15 turnbuckles of 1/2' x 6' are recommended (TEN1/2X6OGJ or TEN1/2X6OQJ).
**NOT using installation accessories such as flanges, tower base, tower anchor, or guy anchors will result in the loss of equipment warranty, and any additional adaptation is the responsibility of the installer.**
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 bands in orange-red and 3 in white.
Lifeline system (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 33 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | Forged 3/8' wire rope clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety carriage for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
New! Lightning Rod + Grounding Kit with Cable. LINKEDPRO brand (Not included)
KLP-TZ30-PRO - All-inclusive! Ideal for 30m towers with crown dipole, wiring, and electrodes.
Or you can individually quote the following Grounding or Lightning rod components:
Recommended Grounding System for Tower and Mounted Equipment (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic junction box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Ground bus bar with 1000A capacity insulators (without enclosure) |
Basic Recommended Lightning Protection System for Tower (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Dipole corona lightning rod tip |
| 1 | TG45AB | 45 Amp. electrode with one bag of enhancing compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic junction box. |
| 1 | ANTIOX | Aerosol for terminal protection. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 20 | TGAC | Down-conductor cable insulator |
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
Recommendations:
- Ensure the installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting).
- It is recommended to illuminate the tower, at least at the top, with a red light.
Representative Diagram: Guy Wire Installation Version 2.0