  • SKU: KTZ-30E-006P

Highlighted Features: Product manufactured under ISO 9001:2015 standards. High Elevation / Low cost. 100% Section-by-Section Assembly Inspection. Electrolytic Galvanization according to ASTM B-633 standard. Ideal for dry, corrosion-free areas Physical...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30E-006P , supplier:Syscom , syscom

Highlighted Features:

  • Product manufactured under ISO 9001:2015 standards.
  • High Elevation / Low cost.
  • 100% Section-by-Section Assembly Inspection.
  • Electrolytic Galvanization according to ASTM B-633 standard.
  • Ideal for dry, corrosion-free areas

Physical Characteristics:

  • Maximum Axial Load: 200 kg.
  • Height: 6 meters (2 sections).
  • Wind resistance: 200 km/hr.
  • Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633).
  • Application: Outdoor (Desert or low-humidity zones)

Includes the following components:

Quantity Model Description
2 STZ30 30 cm face width tower section.
1 SCZ30P 30 cm tower top with lightning rod set screw.
1 SBA30 30 cm tower base.
1 SAB30 Tower base anchor.
1 SJB30 Guy wire attachment flange.
3 SAP01 Slab or wall anchor for guy wire.
6 CUELLO-14-HDG Thimble for guy wire
18 NUDO-316-FJG 3/16' cable clip.

Does not include guy wire. We recommend 32 meters of 1/8' guy wire (SRET-318-CAM ) or larger diameters.

Does not include Turnbuckles. We recommend 3 turnbuckles of 1/2' x 6'. (TEN1/2X6OGJ or TEN1/2X6OQJ).

**The NON-use of installation accessories such as Flanges, Tower Base, Tower Anchor or Guy Wire Anchors is considered a voidance of the equipment warranty, and any additional adaptation is the responsibility of the installer.**

Complementary accessories (Not included):

Signaling/Lighting System (Not included):
Quantity Model Description
2 EIGSLSE Self-contained LED strobe type with photocell, solar panel, and battery. L810 type.
2 HLU3R2 Mount for EIGSLSE obstruction light

*The signaling standard dictates that the tower must be painted in 7 equal-sized stripes; 4 reddish-orange stripes and 3 white stripes.

Lifeline system (Not included):

Quantity Model Description
1 SHE-LV Pair of mounting brackets
1 S-GULV Line guide
9 SRET-338 3/8' cable
6 NUDO-38FJG 3/8' forged clip
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer.
1 SYS-USA7B (Optional) Suspension harness.

*NOM-009 mandates the use of systems that arrest accidental falls on a structure.

New! Lightning Rod Kit + Grounding with cable. LINKEDPRO brand (Not included)

KLP-TZ06-PRO.- All included! Ideal for 6 m towers with corona dipole, wiring, and electrodes.

You can also quote the following Grounding or Lightning rod components individually:

Grounding System Recommended for Tower and Equipment mounted on it (Not included):

Quantity Model Description
1 TG45AB 45 A grounding electrode with Electrode, Filter, and H2Ohm compound
1 S610 Plastic inspection pit.
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 Bonding bar with 1000A capacity insulators (No cabinet)
* We recommend the use of 4 AWG coated copper cable (SLY-287-GRN) for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Basic Recommended Lightning Protection System for Tower (Not included):
Quantity Model Description
1 TGTDPC Lightning rod with Aluminum Mast (MASTIL1.2)
1 TG45AB 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass, and level.
1 S610 Small plastic inspection pit.
1 ANTIOX Terminal protection spray.
3 TGCR11 Eye connector.
2 TGAB18 Rod connector.
4 TGAC

Tower insulator.

*The dipole-type rod offers a 72° protection cone under the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering the electrode is installed at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.

Recommendations:

Ensure that the installation is performed by a trained professional.
Schedule a maintenance plan to check guy wire tension and tighten hardware.
Do not install solar panels at a height of more than 6 meters. Check the compatibility between solar cells and mounts.
A stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failures.
The tower must be painted in reddish-orange and white, in 7 stripes of equal height, starting and ending with reddish-orange (SYSCOM does not perform the tower painting work).
It is recommended to illuminate the tower, at least at the top, with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0

Installation Images