6m Roof-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).

  • $ 12,199.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-30G-006P

Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% inspection of section-by-section assembly Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008 Ideal for high-humidity coastal areas or...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30G-006P , supplier:Syscom , syscom

SYSCOM TOWERS Logo

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost
  • 100% inspection of section-by-section assembly
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal areas or industrial zones

Physical Characteristics

  • Maximum Axial Load: 200 kg
  • Height: 6 meters (2 sections)
  • Wind resistance: 200 km/hr
  • Corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
  • Application: Outdoor (Humid zones)
Includes the following components
Quantity Model Description
2 STZ30G 30 cm face width tower section
1 SCZ30PG 30 cm tower top with set screw for lightning rod
1 SBA30G 30 cm tower base
1 SAB30G Tower base anchor
1 SJB30G Guy wire attachment flange
3 SAP01G Slab or wall anchor for guy wire
6 CUELLO-14-HDG Thimble for guy wire
18 NUDO-316-FJG 3/16' wire rope clip

Does not include guy wire. 32 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.

Does not include turnbuckles. 3 units of 1/2' x 6' turnbuckles are recommended. (TEN1/2X6OGJ or TEN1/2X6OQJ).

**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy anchors will result in the loss of the equipment warranty, and any additional modifications are the responsibility of the installer.**

Complementary accessories (Not included)
Quantity Model Description
2 EIGSLSE Autonomous LED obstruction light with photocell, solar panel, and battery. Type L810
2 HLU3R2 Mount for EIGSLSE obstruction light

*Signaling standards dictate that the tower must be painted in 7 stripes of equal size; 4 reddish-orange stripes and 3 white stripes.

Lifeline system (Not included)
Quantity Model Description
1 SHE-LV Pair of mounting brackets
1 S-GULV Line guide
9 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged cable clip
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer
1 SYS-USA7B (Optional) Suspension harness

*NOM-009 mandates the use of systems that arrest accidental falls on structures.

New! Lightning rod + Grounding kit with cable. Brand: LINKEDPRO (Not included)

KLP-TZ06-PRO. - All-inclusive! Ideal for 6 m towers with crown dipole, wiring, and electrodes.

Alternatively, you may quote the following grounding or lightning rod components individually:

Recommended Grounding System for Tower and Mounted Equipment (Not included)
Quantity Model Description
1 TG45AB 45 A grounding electrode with Electrode, Filter, and H2Ohm compound
1 S610 Plastic inspection pit
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 1000A capacity ground bus bar with insulators (No enclosure)

*It is recommended to use 4 AWG coated copper cable (SLY-287-GRN) to ground the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Recommended Basic Lightning Protection System for Tower (Not included)
Quantity Model Description
1 TGTDPC Lightning rod with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp electrode. With one bag of impedance-improving compound (H2OHM), compass, and level
1 S610 Small plastic inspection pit
1 ANTIOX Terminal protection spray
3 TGCR11 Eye connector
2 TGAB18 Rod connector
2 TGAC Tower insulator

*The dipole-type tip offers a 72° protection cone under the coil. Recommended for areas with low lightning incidence.

*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering a maximum distance of 3 meters from the tower for the electrode, approx. 8 meters are used.

Recommendations
  • Ensure installation is carried out by a trained professional
  • Schedule a maintenance plan to check guy wire tension and tighten hardware
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
  • A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 bands of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting)
  • It is recommended to illuminate the tower at least at the top with a red light

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram Version 2.0

Installation Images

Guyed Tower Installation Images

See the ground connection + lightning rod diagram in the following DIAGRAM