9 m Roof-Mounted Guyed Tower Kit with Galvanized STZ30 Section (guy wire not included).
- $ 12,399.00
- Brand: SYSCOM TOWERS
- Availability: 2 In stock
- SKU: KTZ-30E-009P
Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% inspection of section-by-section assembly Electrolytic galvanization according to ASTM B-633 standards Ideal for dry, corrosion-free areas...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30E-009P , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standards
- High elevation / Low cost
- 100% inspection of section-by-section assembly
- Electrolytic galvanization according to ASTM B-633 standards
- Ideal for dry, corrosion-free areas
Physical Characteristics
- Maximum Axial Load: 200 kg
- Height: 9 meters (3 sections)
- Wind Resistance: 200 km/hr
- Corrosion protection: Electrolytic galvanization (ASTM B-633)
- Application: Outdoor (Desert or low-humidity areas)
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
New! Lightning rod kit + Grounding system with cable. LINKEDPRO brand (Not included)
KLP-TZ09-PRO. - All-inclusive! Ideal for 9 m towers with corona dipole, cabling, and electrodes.
You may also quote the following grounding or lightning rod components individually:
Grounding system recommended for the tower and equipment mounted on it (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic inspection box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Bus bar with insulators, 1000A capacity (Enclosure not included) |
* The use of 4 AWG jacketed copper wire SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic lightning rod system recommended for the tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode with one bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection box |
| 1 | ANTIOX | Terminal protection spray |
| 3 | TGCR11 | Eye Connector |
| 2 | TGAB18 | Rod Connector |
| 2 | TGAC | Tower Insulator |
*The dipole-type tip offers a 72° cone of protection below the coil. Recommended for areas with low lightning incidence. *2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
Recommendations
- Ensure the installation is carried out by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting work)
- It is recommended to light the tower at least at the top with a red lamp