1
/
of
1
EPCOM POWERLINE
Biphase Ferroresonant Industrial Voltage Regulator 2 kVA/2 kW 220 V / Input 176-264 V AC / Output 215.6-224.4 V AC
Biphase Ferroresonant Industrial Voltage Regulator 2 kVA/2 kW 220 V / Input 176-264 V AC / Output 215.6-224.4 V AC
Número de parte: EPL2K2FVR
Regular price
$ 5,199.00
Regular price
Sale price
$ 5,199.00
Taxes included.
Shipping calculated at checkout.
Quantity
Couldn't load pickup availability
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple
Paga con tarjeta, Apple Pay o PayPal
¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096
epcom Powerline EPL2K2FVR Industrial Ferroresonant Voltage Regulator
Main Features
- Rated Power: 2KVA / 2KW, 100% capacity with copper wiring.
- Smart Design: CPU smart control to support all types of loads.
- Quality Components: PCB with SMT process and electronic components from imported brands.
- LCD Screen: Easy configuration and real-time monitoring.
- Advanced Protection: Against overvoltage, undervoltage, overload, short circuit, and bypass.
- Optional Remote Control
Technical Specifications
- Model: EPL2K2FVR
- Control Methodology: Servo Motor with CPU microprocessor.
- Stabilization: ±2% Adjustable.
- Power Factor: PF ≥ 1
- Efficiency: ≥ 98%.
- Response Time: ≤ 0.5S.
- Delay Time [ON]: ≤ 5s [Optional].
- Wave Distortion: ≤ 1%.
Input
- Rated Voltage: 2 x 120VAC [2F + N].
- Voltage Range: 176VAC - 264VAC.
- Frequency: 50/60 Hz.
Output
- Rated Voltage: 220VAC [2F].
- Stabilization: ±2% Adjustable.
- Note: Does not have split-phase output.
Protection System
- Overvoltage: Output cutoff when output voltage is higher than 10% [adjustable], in 3 - 5 s.
- Undervoltage: Output cutoff when output voltage is lower than 10% [adjustable], in 3 - 5 s.
- Overload: Output cutoff in case of overcurrent, in 3 - 5 s.
- Short Circuit: Output cutoff during short circuit, in 3 - 5 s.
- Bypass: Manual transfer to bypass when the AVR fails or is undergoing maintenance.
LCD Screen
- Input Voltage: Real-time display.
- Output Voltage: Real-time display.
- Input Current: Real-time display.
- Protections: Active protection indicator.
Other
- Cooling System: Convection.
- Insulation Resistance: ≥2MΩ.
- Voltage Resistance: 2000VAC/min without failure.
- Noise Level: <65dB/m.
Operating Environment
- Operating Temperature: 0°C-45°C (non-condensing).
- Operating Humidity: 20%-90%.
Dimensions and Weight
- Dimensions (WxHxL): 280 x 320 x 530 mm.
- Net Weight: 19.5 kg.
- Gross Weight: 28.5 kg.
NOTE 1: It is recommended to conduct a prior study to review the electrical installation conditions.
NOTE 2: If the regulator is fed with a high voltage and an even higher voltage is obtained at the output, this is a symptom of a phase angle mismatch in the phases powering the regulator. This must be corrected by powering the regulator from an isolated transformer.
NOTE 3: Does not include a power cord; it is necessary to assemble one with the gauge and plug corresponding to the voltage and capacity.