Wishlist

Ferroresonant Two-Phase Industrial Voltage Regulator 5 kVA/5 kW 220 V / Input 176-264 VAC / Output 215.6-224.4 VAC

  • $ 7,599.00
  • Brand: EPCOM POWERLINE
  • Availability: In stock
  • SKU: EPL5K2FVR

Key Features Rated Power: 5KVA / 5KW, 100% capacity with copper wiring. Intelligent Design: Intelligent CPU control to support all types of loads. Quality Components: PCB with SMT process and...

Tags: categoria:Energía / Herramientas , marca:EPCOM POWERLINE , proveedor:Syscom , sku:EPL5K2FVR , supplier:Syscom , syscom

Key Features

  • Rated Power: 5KVA / 5KW, 100% capacity with copper wiring.
  • Intelligent Design: Intelligent CPU control to support all types of loads.
  • Quality Components: PCB with SMT process and imported electronic components.
  • LCD Screen: Easy setup and real-time monitoring.
  • Advanced Protection: Against overvoltage, undervoltage, overload, short circuit, and bypass.
  • Optional Remote Control
Technical Specifications
  • Model: EPL5K2FVR
  • Control Methodology: Servo Motor with CPU microprocessor.
  • Stabilization: ±2% Adjustable.
  • Power Factor: PF ≥ 1
  • Efficiency: ≥ 98%.
  • Response Time: ≤ 0.5S.
  • Delay Time [ON]: ≤ 5s [Optional].
  • Wave Distortion: ≤ 1%.
Input
  • Rated Voltage: 2 x 120VAC [2F + N].
  • Voltage Range: 176VAC - 264VAC.
  • Frequency: 50/60 Hz.
Output
  • Rated Voltage: 220VAC [2F].
  • Stabilization: ±2% Adjustable.
  • Does not have split-phase output.
Protection System
  • Overvoltage: Output cutoff when output voltage is > 10% [adjustable], in 3 - 5 s.
  • Undervoltage: Output cutoff when output voltage is < 10% [adjustable], in 3 - 5 s.
  • Overload: Output cutoff in case of overcurrent, in 3 - 5 s.
  • Short Circuit: Output cutoff during short circuit, in 3 - 5 s.
  • Bypass: Manual transfer to bypass when the AVR fails or is undergoing maintenance.
LCD Screen
  • Input Voltage: Real-time display.
  • Output Voltage: Real-time display.
  • Input Current: Real-time display.
  • Protections: Active protection indicator.
Operating Environment
  • Operating Temperature: 0°C-45°C (non-condensing).
  • Operating Humidity: 20%-90%.
Dimensions and Weight
  • Dimensions (WxHxD): 400 x 615 x 400 mm. Height of 61.5 cm with casters.
  • Net Weight: 33 kg.
  • Gross Weight: 48 kg.
Others
  • Cooling System: Convection.
  • Insulation Resistance: ≥2MΩ.
  • Voltage Resistance: 2000VAC/min without damage.
  • Noise Level: <65dB/m

NOTE 1:

A prior study is recommended to check the conditions of the electrical installation.

NOTE 2:

If the regulator is powered with a high voltage and the output voltage is even higher, this is a symptom of a phase angle offset in the phases feeding the regulator. This must be corrected by powering the regulator from an isolated transformer.

NOTE 3:

Does not include power cable; it is necessary to assemble one with the gauge and plug corresponding to the voltage and capacity.

Recently viewed