Skip to product information
1 of 1

EPCOM POWERLINE

Single-Phase Ferroresonant Industrial Voltage Regulator 3 kVA/3 kW 120 V / Input 96-144 VAC / Output 117.6 - 122.4 VAC

Single-Phase Ferroresonant Industrial Voltage Regulator 3 kVA/3 kW 120 V / Input 96-144 VAC / Output 117.6 - 122.4 VAC

Número de parte: EPL3K1FVR
Regular price $ 6,699.00
Regular price Sale price $ 6,699.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple Paga con tarjeta, Apple Pay o PayPal ¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096

Key Features

  • Rated Power: 3KVA / 3KW, 100% capacity with copper wiring.
  • Intelligent Design: Intelligent CPU control to support all types of loads.
  • Quality Components: PCB with SMT process and electronic components from imported brands.
  • LCD Display: Easy configuration and real-time monitoring.
  • Advanced Protection: Against overvoltage, undervoltage, overload, short circuit, and bypass.
  • Optional Remote Control
Technical Specifications
  • Model: EPL3K1FVR
  • Control Methodology: Servo Motor with CPU microprocessor.
  • Stabilization: ±2% Adjustable.
  • Power Factor: PF ≥ 1
  • Efficiency: ≥ 98%.
  • Response Time: ≤ 0.5S.
  • Delay Time [ON]: ≤ 5s [Optional].
  • Waveform Distortion: ≤ 1%.
Input
  • Rated Voltage: 1 x 120VAC [1Ph + N].
  • Voltage Range: 96VAC - 144VAC.
  • Frequency: 50/60 Hz.
Output
  • Rated Voltage: 1 x 120VAC [1Ph + N].
  • Stabilization: ±2% Adjustable.
Protection System
  • Overvoltage: Output cut-off when output voltage is 10% [adjustable] above nominal, in 3 - 5 s.
  • Undervoltage: Output cut-off when output voltage is 10% [adjustable] below nominal, in 3 - 5 s.
  • Overload: Output cut-off in case of overcurrent, in 3 - 5 s.
  • Short Circuit: Output cut-off during short circuit, in 3 - 5 s.
  • Bypass: Manual transfer to bypass when AVR fails or requires maintenance.
LCD Display
  • Input Voltage: Real-time display.
  • Output Voltage: Real-time display.
  • Input Current: Real-time display.
  • Protections: Active protections indicator.
Other
  • Cooling System: Convection.
  • Insulation Resistance: ≥2MΩ.
  • Voltage Withstand: 2000VAC/min without failure.
  • Noise Level: <65dB/m
Operating Environment
  • Operating Temperature: 0°C-45°C (non-condensing).
  • Operating Humidity: 20%-90%.
Dimensions and Weight
  • Dimensions (WxHxD): 243 x 320 x 342 mm.
  • Net Weight: 15.5 kg.
  • Gross Weight: 17 kg.

Important Notes

NOTE 1: It is recommended to conduct a prior study to review the conditions of the electrical installation.

NOTE 2: In case the regulator is powered with a high voltage and an even higher voltage is obtained at the output, this is a sign of a phase angle mismatch in the power supply phases. This should be corrected by powering the regulator from an isolation transformer.

NOTE 3: It does not include a power cord; it is necessary to assemble one with the appropriate gauge and plug for the voltage and capacity.


View full details