Technical Characteristics
- Model: 1601010
- Compatibility: Doorking barriers models 1601, 1602
- Application: Vehicular access control
- Material: Weather resistant
- Installation: Concrete pad mounting
Electrical Specifications
- Voltage: 115 VAC
- Connection: High voltage (requires grounding)
- DIP Switches: Function configuration
- Sensor connection: Terminals for contact and non-contact sensors
Configuration
- SW1-1: Model 1601 (OFF), 1602 (ON)
- SW1-7: Automatic timer (1-59 seconds)
- SW2-4: Down loop operation
- SW1-5: Relay activation (DOWN loop or UP loop)
Dimensions
- Mounting: Concrete pad (48h cure)
- Sensor height: 21' typical, 27.5' maximum
- Conduit: 4' minimum above ground
Safety
- Requires grounding
- Reverse with 0.5-second delay
- Requires clear area for manual operation
- Pedestrian access separation
Applications
- Vehicular entry lanes
- One-way traffic control
- Installation with detection loops
- Operation with optical sensors
DIP-Switch Configuration
- SW1-1: 1601 (OFF), 1602 (ON)
- SW1-7: Automatic timer (1-59 sec)
- SW2-4: Loop/reverse function
- SW1-5: Loop-activated relay
Main Functions
- Stop during down cycle
- Multiple input memory
- Automatic self-test
- 360° or 180° gear usage
Connections
- Detection loop (not included)
- Connector for loop detector
- Connection for external antenna
- Connection for safety sensors
Installation Notes
- Verify DIP-Switch configuration before powering on
- Allow concrete to fully cure (48 hours)
- Mount arm with operator in the down position
- Verify electrical connections and grounding
- Consult installation manual for advanced settings
Precautions
- Never use for pedestrian access
- Avoid manual operation without ensuring a clear area
- Do not modify configuration without turning off equipment
- Keep installation manual for reference
- Do not install in areas with electrical interference
Reference Manual
For advanced settings, installation, and safety, consult the DoorKing installation/user manual, and the detection loops manual.
Location
Manufactured by DoorKing, Inc. in the United States (120 S. Glasgow Avenue, Inglewood, CA 90301)
Reference