Skip to product information
1 of 1

Ruiz Electronics

Interlock Control Board for 2 Doors with Unlock and Lock Timer / Emergency Button Input

Interlock Control Board for 2 Doors with Unlock and Lock Timer / Emergency Button Input

Número de parte: RXC02
Regular price $ 1,799.00
Regular price Sale price $ 1,799.00
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple Paga con tarjeta, Apple Pay o PayPal ¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096

Main Features

  • Controls 2 doors with relay outputs
  • Doors normally unlocked or locked depending on configuration
  • 2 inputs for door sensor (NC - Dry contact)
  • 2 inputs for push-button type switch (NO - Dry contact)
  • 1 input for emergency button (NO - Dry contact)
  • 3 relay outputs: 2 for door control and 1 for emergency exit
  • Opening standby activation timer: 0 to 30 seconds
  • Door opening time timer: 0 to 30 seconds
  • Power supply: 12 VDC
  • Dimensions: 10.95 x 7.2 x 2.5 cm
  • NOTE: Not for use with Electric Locks.

Operation Modes

  • Doors normally unlocked: When opening one door, the second is automatically locked. To unlock again, it is required to close the open door. A time is set between the closing of the first door and the unlocking of the second (0-30 seconds). Configuration: Jumper on B1 and B2.
  • Doors normally locked: Requires a button to unlock the desired door (B1/B2). A time is set between button press and unlocking (0-30 seconds) and time before locking again (0-30 seconds). Upper selector for unlocking time, lower selector for locking time.

Timing Configuration

The timers are configured using the SW1 to SW4 selectors, with a predefined configuration table:

SW1 SW2 SW3 SW4 Time (sec)
0 0 0 0 0
0 0 0 1 2
0 0 1 0 4
0 0 1 1 6
0 1 0 0 8
0 1 0 1 10
0 1 1 0 12
0 1 1 1 14
1 0 0 0 16
1 0 0 1 18
1 0 1 0 20
1 0 1 1 22
1 1 0 0 24
1 1 0 1 26
1 1 1 0 28
1 1 1 1 30

Emergency Operation

The card includes an emergency input that, when activated, triggers both relays to release the doors. This input requires a latching-type emergency button for its activation.

Configuration and Settings

  • Upper selector: Configures the time between the button press and the door unlocking (0-30 seconds)
  • Lower selector: Configures the time before locking the door again (0-30 seconds)
  • Jumper B1 and B2: Enables the normally unlocked doors mode

Additional Information

  • Warranty: 1 year
  • Availability: Available since January 2017

Reference Video

View full details