LinkedPro
30 kVA UPS / Online Double Conversion / 3-Phase 200-240 VAC / PF 1.0 / Up to 6 in Parallel / Hardwired Terminal
30 kVA UPS / Online Double Conversion / 3-Phase 200-240 VAC / PF 1.0 / Up to 6 in Parallel / Hardwired Terminal
Couldn't load pickup availability
LinkedPro by EPCOM · LP30KYDC · Three-Phase UPS
Power that doesn't ask. It responds.
30 kVA three-phase backup with unity power factor. 94% efficiency. 0-millisecond transfer. Up to 6 units in parallel. For the data center that cannot stop.
Real Power
30 kVA equals 30 kW.
1.0 power factor. Every watt you pay for, you use. No correction, no penalties. Inductive, capacitive, unbalanced loads—it handles them all without complaint.
Output PF 1.0 · Input PF ≥0.99 · THDi ≤3% · Pure sine wave
Efficiency
Less heat, more backup.
94% efficiency with a 3-level IGBT inverter. This translates to less thermal loss, less air conditioning, and an electric bill that doesn't skyrocket. Your data center chiller will thank you.
3-level inverter · THDv ≤2% · ECO Mode · 66 dB max
Scalability
Grow without changing architecture.
Up to 6 units in parallel with shared batteries. Start with 30 kVA and scale up to 180 kVA when the business demands it. No need to redesign your electrical room or migrate to another ecosystem.
6x parallel · Shared batteries · N+1 redundancy · No single point of failure
Total Protection
From the dirtiest voltage to total power outages.
132 to 275 VAC input range without power derating. Where other UPS units have already cut back, this one keeps delivering 100%. 0 ms transfer time. Your switch won't even notice the power went out.
132-275 VAC · 0 ms transfer · 110% overload for 60 min · Short-circuit protection
Where it works non-stop
Technical Specifications
Voltage: 208/120 or 220/127 Vac, 3P+N+PE
Range: 132-275 Vac (50% load), 176-275 (100%)
Frequency: 40-70 Hz
THDi: ≤3%
PF: ≥0.99
Voltage: 208/120 or 220/127 Vac, ±1%
PF: 1.0
THDv: ≤2% (linear load)
Efficiency: 94%
Overload: 110% 60 min / 150% 1 min
Configuration: 16-26 batteries per group
DC Voltage: ±192 to ±312 Vdc
Max Charge: 40 A
Banks: External (not included)
Shared: Yes, in parallel
Dimensions: 300 x 800 x 1000 mm
Weight: 96 kg
Temperature: 0-40°C
Humidity: 0-95% RH
Noise: <66 dB
Certifications: UL 1778, CSA, FCC, Energy Star 2.0
Warranty and Support
3 years. No fine print.
3-year factory warranty. Replacement part PWRLP30KYDC available. Communication: USB, RS232, RS485, dry contact, and SNMP (optional). Compatible with centralized monitoring and management systems.
Spare Parts
Original spare parts available for this model:
PWRLP30KYDC — Replacement Power Board for UPS LP30KYDC (LinkedPro YDC Series 30 kVA Three-Phase)